Jumpers
PHYTEC Messtechnik GmbH 2005 L-645e_1
31
Jumper
Default Comment
J34
J34 connects the global clock input XPLD_CLK2 to the signal
XPLD0_34 of the XPLD logic device. This feature may be
used to establish a wired feedback of a software controlled
global clock signal.
open
X
XPLD_CLK2 is not connected to XPLD0_34.
closed
XPLD_CLK2 is connected to XPLD0_34.
Package Type
0R in SMD 0402
J35
J35 connects the digital ground to the analog ground.
open
GND is not connected to GNDA.
closed
X
GND is connected to GNDA.
Package Type
0R in SMD 0805
J36
J36 selects the VCAN power supply for the CAN transceivers
at U10 and U11 depending on the devices populating the
module.
1 + 2
X
VCAN is connected to +3V3.
2 + 3
VCAN is connected to VIN5V.
Package Type
0R in SMD 0805
J37
Test point for +2V5 voltage.
J38
Test point for +1V5 voltage.
Table 2:
Jumper Settings