3.
Click on
CalibrateBlack
(in category
Calibration
). Wait until the command has been
finished, i.e.the property
Correction_Busy
(in category
Calibration
) is 0.
Correction_Busy
can
be updated by clicking on the property Correction_BusyUpdate (in category
Calibration
).
6.5.3
Storing the calibration in permanent memory
After running calibration procedures (see Section 6.5.1 and Section 6.5.2) the calibration values
are stored in RAM. When the camera is turned off, their values are deleted.
To prevent this, the calibration values must be stored in flash memory. This can be done by
clicking on the property
Correction_SaveToFlash
(in category
Calibration
). Wait until the
command has been finished, i.e.the property
Correction_Busy
(in category
Calibration
) is 0.
Correction_Busy
can be updated by clicking on the property Correction_BusyUpdate (in
category
Calibration
).
6.6
Look-Up Table (LUT)
6.6.1
Overview
The LUT is described in detail in Section 4.8. All LUT settings can be set in the GUI
(PF_GEVPlayer ). There are LUT setting examples in the PFInstaller, that can be downloaded
from the Photonfocus webpage.
To manually set custom LUT values in the GUI is practically not feasable as up to
4096 values for every LUT must set. This task should be done with the SDK.
If LUT values should be retained in the camera after disconnecting the power,
then they must be saved with
UserSetSave
6.6.2
Full ROI LUT
This section describe the settings for one LUT that is applied to the full ROI.
1.
Set
LUT_EnRegionLUT
(in category
RegionLUT
) to False. This is required to use the full ROI LUT.
2.
Set
LUTEnable
(in category
LUTControl
) to False. This is not mandatory but recommended.
3.
Select LUT 0 by setting
LUTSelector
(in category
LUTControl
) to 0.
4.
Set LUT content as described in Section 6.6.4.
5.
Turn on LUT by setting
LUTEnable
to True.
6.6.3
Region LUT
The Region LUT feature is described in Section 4.8.4. Procedure to set the Region LUT:
1.
Set
LUT_EnRegionLUT
(in category
RegionLUT
) to False. This is not mandatory but
recommended.
2.
Set
LUTEnable
(in category
LUTControl
) to False. This is not mandatory but recommended.
3.
Select LUT 0 by setting
LUTSelector
(in category
LUTControl
) to 0.
4.
Set properties LUT_X, LUT_W, LUT_Y and LUT_H (all in category
RegionLUT
) to desired
value.
6.6 Look-Up Table (LUT)
97
Summary of Contents for MV1-D2080(IE) Series
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 14: ...2 How to get started GigE G2 Figure 2 3 PFInstaller components choice 12...
Page 32: ...3 Product Specification 30...
Page 53: ...Figure 4 27 Trigger Inputs Multiple GigE solution 4 4 Trigger and Strobe 51...
Page 74: ...4 Functionality Figure 4 50 Unsharp Mask Examples 72...
Page 82: ...4 Functionality 80...
Page 110: ...7 Mechanical and Optical Considerations 108...
Page 112: ...8 Warranty 110...
Page 114: ...9 References 112...
Page 118: ...B Camera Revisions 116...