6 Software
5.
Set LUT content as described in Section 6.6.4.
6.
If two Region LUT are required, then select LUT 1 by setting
LUTSelector
(in category
LUTControl
) to 1 and repeat steps 4 and 5.
7.
Turn on LUT by setting
LUTEnable
to True.
8.
Turn on Region LUT by setting
LUT_EnRegionLUT
(in category
RegionLUT
) to False.
6.6.4
User defined LUT settings
This section describes how to set user defined LUT values. It is assumed that the LUT was
selected as described in Section 6.6.2 or Section 6.6.3.
For every LUT value the following steps must be done:
1.
Set
LUTIndex
(in category
LUTControl
) to desired value. The
LUTIndex
corresponds to the
grey value of the 12 bit input signal of the LUT.
2.
Set
LUTValue
(in category
LUTControl
) to desired value. The
LUTValue
corresponds to the
grey value of the 8 bit output signal of the LUT.
The
LUTIndex
is auto incremented internally after setting a
LUTValue
. If consec-
utive
LUTIndex
are written, then it is required to set
LUTIndex
only for the first
value. For the next values it is sufficient to set only the
LUTValue
.
6.6.5
Predefined LUT settings
Some predefined LUT are stored in the camera. To activate a predefined LUT:
1.
Select LUT and RegionLUT (if required) as described in Section 6.6.2 and Section 6.6.3.
2.
Set
LUTAutoMode
(in category
LUTControl
) to the desired value. The available settings are
described in property list of the camera which is contained in the PFInstaller.
3.
If the
LUTAutoMode
requires additional settings (e.g. Gamma
LUTAutoMode
), then it can be set
with
LUTAutoValue
.
6.7
MROI
The MROI feature is described in Section 4.3.3. This section describes how to set the MROI
values.
When MROI is enabled, then the camera internally processes the MROI entries sequentially,
starting at
MROI_Index
0. The processing is stopped when either the last
MROI_Index
is reached or
when an entry with
MROI_Y
=2079 is reached.
Procedure to write MROI entries:
1.
Disable MROI by setting
MROI_Enable
to False. This is mandatory otherwise setting the
MROI entries will be ignored.
2.
Set
MROI_Index
. In the first run it is set to 0 and then incremented in every run.
3.
Set
MROI_Y
to the starting row of the MROI.
4.
Set
MROI_H
to the height of the MROI.
5.
Proceed with step 2, incrementing the
MROI_Index
. If no more MROI should be set, then
run the steps 2 to 4 again (incrementing
MROI_Index
) but set
MROI_Y
to the value 2079.
6.
Enable MROI by setting
MROI_Enable
to True.
98
Summary of Contents for MV1-D2080(IE) Series
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 14: ...2 How to get started GigE G2 Figure 2 3 PFInstaller components choice 12...
Page 32: ...3 Product Specification 30...
Page 53: ...Figure 4 27 Trigger Inputs Multiple GigE solution 4 4 Trigger and Strobe 51...
Page 74: ...4 Functionality Figure 4 50 Unsharp Mask Examples 72...
Page 82: ...4 Functionality 80...
Page 110: ...7 Mechanical and Optical Considerations 108...
Page 112: ...8 Warranty 110...
Page 114: ...9 References 112...
Page 118: ...B Camera Revisions 116...