4.8.3
User-defined Look-up Table
In the ’User’ mode, the mapping of input to output grey levels can be configured arbitrarily by
the user. There is an example file in the PFRemote folder. LUT files can easily be generated
with a standard spreadsheet tool. The file has to be stored as tab delimited text file.
U s e r L U T
y = f ( x )
1 2 b i t
8 b i t
Figure 4.42: Data path through LUT
4.8.4
Region LUT and LUT Enable
Two LUTs and a Region-LUT feature are available in the MV1-D2080(IE) camera series. Both
LUTs can be enabled independently (see Table 4.7). LUT 0 superseds LUT1.
When Region-LUT feature is enabled, then the LUTs are only active in a user defined region.
Examples are shown in Fig. 4.43 and Fig. 4.44.
Fig. 4.43 shows an example of overlapping Region-LUTs. LUT 0, LUT 1 and Region LUT are
enabled. LUT 0 is active in region 0 ((x00, x01), (y00, y01)) and it supersedes LUT 1 in the
overlapping region. LUT 1 is active in region 1 ((x10, x11), (y10, y11)).
Fig. 4.44 shows an example of keyhole inspection in a laser welding application. LUT 0 and LUT
1 are used to enhance the contrast by applying optimized transfer curves to the individual
regions. LUT 0 is used for keyhole inspection. LUT 1 is optimized for seam finding.
Fig. 4.45 shows the application of the Region-LUT to a camera image. The original image
without image processing is shown on the left-hand side. The result of the application of the
Region-LUT is shown on the right-hand side. One Region-LUT was applied on a small region on
the lower part of the image where the brightness has been increased.
Enable LUT 0
Enable LUT 1
Enable Region LUT
Description
-
-
-
LUT are disabled.
X
don’t care
-
LUT 0 is active on whole image.
-
X
-
LUT 1 is active on whole image.
X
-
X
LUT 0 active in Region 0.
X
X
X
LUT 0 active in Region 0 and LUT 1 active
in Region 1. LUT 0 supersedes LUT1.
Table 4.7: LUT Enable and Region LUT
.
4.8 Grey Level Transformation (LUT)
67
Summary of Contents for MV1-D2080(IE) Series
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 14: ...2 How to get started GigE G2 Figure 2 3 PFInstaller components choice 12...
Page 32: ...3 Product Specification 30...
Page 53: ...Figure 4 27 Trigger Inputs Multiple GigE solution 4 4 Trigger and Strobe 51...
Page 74: ...4 Functionality Figure 4 50 Unsharp Mask Examples 72...
Page 82: ...4 Functionality 80...
Page 110: ...7 Mechanical and Optical Considerations 108...
Page 112: ...8 Warranty 110...
Page 114: ...9 References 112...
Page 118: ...B Camera Revisions 116...