4.8 Grey Level Transformation (LUT)
a
y = f ( x )
x
x
m a x
x
0
x
1
y
m a x
b
c
d
Figure 4.37: Commonly used LUT transfer curves
0
200
400
600
800
1000
1200
0
50
100
150
200
250
300
Grey level transformation − Gain: y = (255/1023)
⋅
a
⋅
x
x: grey level input value (10 bit) [DN]
y: grey level output value (8 bit) [DN]
a = 1.0
a = 2.0
a = 3.0
a = 4.0
Figure 4.38: Applying a linear gain with clamping to an image
MAN064 02/2020 V1.1
51 of 109
Summary of Contents for MV1-D1024E
Page 6: ...CONTENTS 6 of 109 MAN064 02 2020 V1 1...
Page 10: ...1 Preface 10 of 109 MAN064 02 2020 V1 1...
Page 14: ...2 How to get started CameraLink Figure 2 4 PFRemote start window 14 of 109 MAN064 02 2020 V1 1...
Page 68: ...5 Precautions 68 of 109 MAN064 02 2020 V1 1...
Page 94: ...8 Graphical User Interface GUI 94 of 109 MAN064 02 2020 V1 1...
Page 104: ...12 References 104 of 109 MAN064 02 2020 V1 1...