3 Product Specification
3.6
Frame Grabber relevant Configuration
The parameters and settings, which are essential to configure the frame grabber are shown in
the following table.
MV1-D10124E-160-CL
Pixel Clock per Tap
80 MHz
Number of Taps
2
Greyscale resolution
12 bit / 10 bit / 8 bit
Line pause
8 clock cycles
CC1
EXSYNC
CC2
not used
CC3
not used
CC4
not used
Maximal average data rate @ 8 bit
160 MB/s
Maximal average data rate @ 10/12 bit
1)
320 MB/s
Table 3.5: Summary of parameters needed for frame grabber configuration (Footnotes:
1)
assuming 16
bit/pixel data transmission)
CameraLink
®
port and bit assignments are compliant with the CameraLink
®
standard (see [CL]).
Table 3.6 shows the tap configuration for the MV1-D1024E-160-CL camera.
Bit
Tap 0
Tap 1
Tap 0
Tap 1
Tap 0
Tap 1
8 Bit
8 Bit
10 Bit
10 Bit
12 Bit
12 Bit
0 (LSB)
A0
B0
A0
C0
A0
C0
1
A1
B1
A1
C1
A1
C1
2
A2
B2
A2
C2
A2
C2
3
A3
B3
A3
C3
A3
C3
4
A4
B4
A4
C4
A4
C4
5
A5
B5
A5
C5
A5
C5
6
A6
B6
A6
C6
A6
C6
7 (MSB of 8 Bit)
A7
B7
A7
C7
A7
C7
8
-
-
B0
B4
B0
B4
9 (MSB of 10 Bit)
-
-
B1
B5
B1
B5
10
-
-
-
-
B2
B6
11 (MSB of 12 Bit)
-
-
-
-
B3
B7
Table 3.6: CameraLink
®
2 Tap port and bit assignments for the MV1-D1024E-160 camera
20 of 109
MAN064 02/2020 V1.1
Summary of Contents for MV1-D1024E
Page 6: ...CONTENTS 6 of 109 MAN064 02 2020 V1 1...
Page 10: ...1 Preface 10 of 109 MAN064 02 2020 V1 1...
Page 14: ...2 How to get started CameraLink Figure 2 4 PFRemote start window 14 of 109 MAN064 02 2020 V1 1...
Page 68: ...5 Precautions 68 of 109 MAN064 02 2020 V1 1...
Page 94: ...8 Graphical User Interface GUI 94 of 109 MAN064 02 2020 V1 1...
Page 104: ...12 References 104 of 109 MAN064 02 2020 V1 1...