4.2 Pixel Response
®
0
20
40
60
80
100
120
140
160
180
200
Typical LinLog2 Response Curve − Varying Parameter Time1
Illumination Intensity
Output grey level (8 bit) [DN]
T1 = 880
T1 = 900
T1 = 920
T1 = 940
T1 = 960
T1 = 980
T1 = 1000
Time2=1000, Value1=19, Value2=18
Figure 4.12: Response curve for different LinLog settings in LinLog2 mode
LinLog3
To enable more flexibility the LinLog3 mode with 4 parameters was introduced. Fig. 4.13 shows
the timing diagram for the LinLog3 mode and the control parameters.
V
L i n L o g
t
V a l u e 1
V a l u e 2
t
e x p
T
i m
e 2
T i m
e 1
T i m e 1
T i m e 2
t
e x p
V a l u e 3 = C o n s t a n t = 0
Figure 4.13: Voltage switching in the LinLog3 mode
MAN064 02/2020 V1.1
27 of 109