![Phonowind Phono W-1.0 Owner'S Manual Download Page 44](http://html1.mh-extra.com/html/phonowind/phono-w-1-0/phono-w-1-0_owners-manual_1553386044.webp)
Appendix: D
40
Main circuit connecting cable diameters
1 Kw
2 Kw
3 Kw
Project
Description
Maximum
Current
Cable
Maximum
Current
Cable
Maximum
Current
Cable
Generator Output
(connection distance ≤100m)
Wind generator
input AC
8A
4mm
2
×4
16A
6mm²×4
12
4mm²×4
Controller Output
(connection distance ≤20M)
DC output
(+,-)
20A
6mm²×2
35A
6mm²×2
15
6mm²×2
Controller Unloading
(connection distance ≤20m)
Diversion Load
24A
6mm²×2
45A
6mm²×2
24
6mm²×2
Controller Input
(connection distance≤30m)
L,N
/
/
/
/
0.2
2mm²×2
Ground Connection
(connection distance≤50m)
Connect to ground
/
6mm²×1
/
6mm²×1
/
6mm²×1
5 Kw
10 Kw
Project
Description
Maximum
Current
Cable
Maximum
Current
Cable
Generator Output
(connection distance ≤100m)
Wind generator
input AC
20
6mm²×4
20
6mm²×4
Controller Output
(connection distance ≤20M)
DC output
(+,-)
24
6mm²×2
24
6mm²×2
Controller Unloading
(connection distance ≤20m)
Diversion Load
30
6mm²×2
29
6mm²×2
Controller Input
(connection distance≤30m)
L,N
0.2
2mm²×2
0.2
2mm²×2
Ground Connection
(connection distance≤50m)
Connect to ground
/
6mm²×1
/
6mm²×1
Summary of Contents for Phono W-1.0
Page 1: ...OWNER S MANUAL Installation Operation Maintenance...
Page 19: ...15 Installation Flow Chart...
Page 24: ...20 Step 1 Step 2 Step 3 B A A A...
Page 25: ...21 Step 4 Step 5 Step 6 Overturn Overturn...
Page 26: ...22 L1 L2 L3 L1 L2 L3 3mm...
Page 29: ...25 Connections of Tail Rudder and Generator Step 1 Step 2 Step 4 Step 3...