background image

ICON 300/00

100 volt line output connection

Bridge Mono Configuration for Audio Transformer Outputs

1. For driving 140V or 200V distributed lines, the amplifier must 

be set into bridge mono mode.

2.  Connect  the  signal  to  channel  1's  input  only.  Do  not 

connect an input signal to channel 2.

3. 

Use only channel 1's gain control to set the level.

 Both 

channels  signal  and  clip  indicators  should  flash  identically 

when the amplifier is operating.

140 volt line output connection, 

bridge mono mode

200 volt line output connection, 

bridge mono mode

 

Parallel Mono Configuration

The  "Parallel  mode"  ties  the  two  channel  inputs  together  so 

that both are driven by the same signal, without the need for 

external  jumpers  or  wiring.  After  the  inputs,  both  channels 

operate independently. Though they carry the same signal, their 

gain controls affect only their respective channels, which must 

be  used  separately.  Please  refer  to  the  previous  Rear  Panel 

Description.

 Never parallel the speaker outputs.

 

Low-Impedance  and  Distributed  Speakers  on  Icon 

Amplifiers

If your application calls for connection of an 8 ohm speaker and 

a distributed line to the same amplifier channel, the Icon 300 

and  Icon  700  are  among  the  very  few  amplifiers  that  can  do 

that. However, since most of the audio power is drawn by the 

direct-connected speaker, you must derate the distributed line; 

and the distributed line should have a total power load of no 

more  than  one-fourth  of  the  amplifiers  normal  distributed  line 

power rating.

 

Computing maximum allowable distributed line load with a 

known low-impedance load

MaxTOP = [MaxRatedPL - ((2 x MaxRatedPL)/Impedance)]/2

 

MaxTOP is the sum of the power taps of the speakers connected 

to the Audio Transformer outputs.

MaxRatedPL is the maximum rated power of the amplifier into 

a two ohm load.

Impedance  is  the  load  impedance  connected  to  the  direct 

outputs.

Example:  One  channel  of  an  Icon  700  has  an  8-ohm  load 

connected  to  the  Direct  (low  impedance)  output.  Then  the 

maximum  power  left  available  to  drive  a  distributed  line  is: 

MaxTOP = [550-((2x550/8)/2)] = 206 Watts

Summary of Contents for ICON300

Page 1: ...User s Manual Manual del Usuario ICON300 ICON700 CONTRACTOR POWER AMPLIFIER AMPLIFICADOR DE POTENCIA PARA CONTRATISTA ICON300 ICON700 English Espa ol...

Page 2: ...ciones 10 Acerca de Este Manual 10 Panel Frontal 11 Panel Trasero 11 Conexiones de Entrada Balanceada de bornes de Seguridad 12 Conexiones de Salida de los Bornes de Seguridad 12 Salidas del Transform...

Page 3: ...hting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug...

Page 4: ...Toroidal output transformers provide full electrical isolation and meet worldwide safety agency approval Built in 45 Hz subsonic filter prevents speaker transformer saturation with minimal effect on...

Page 5: ...s a built in limiter on each channel to prevent clipping Should the signal reach a level high enough to cause clipping ie output power is over 400W per channel the limiter momentarily reduces the inpu...

Page 6: ...type shown are recommended Always make sure the amplifier is turned off before you change any output connections Loose screw terminals insert wire connectors under screws Tighten screw terminals Dire...

Page 7: ...r Panel Description Never parallel the speaker outputs Low Impedance and Distributed Speakers on Icon Amplifiers If your application calls for connection of an 8 ohm speaker and a distributed line to...

Page 8: ...2dB Input Impedance Balanced Unbalanced 20k 10k ohm Damping Factor 200 direct output S N Ratio Less than 100dB below rated output 20Hz 20kHz Protection Circuits Output offset voitage protection Heat s...

Page 9: ......

Page 10: ...Toroidales de salida que proveen de aislamiento el ctrico total y concuerdan con las especificaciones de seguridad internaciones les Filtro subs nico integrado a 45 Hz que previene que los transformad...

Page 11: ...ejem la potencia de salida es de m sde400Wporcanal elimitadorreducir moment neamente el nivel de la se al de entrada solo lo suficiente para prevenir esto El LED de limitaci n se encender cuando esto...

Page 12: ...eg rate de que el amplificador este apagado antes de cambiar cualquier conexi n de salida Liberal los tornillos de las terminales inserta las conexiones de los cables debajo de los tornillos Aprieta f...

Page 13: ...asero Nunca pongas en paralelo las dos salidas Altavoces Distribuidos y de Baja Impedancia en los Ampli ficadores Icon SI tus aplicaciones necesitan la conexi n de altavoces de 8 ohm y una l nea distr...

Page 14: ...tor Damping 200 Salida directa Relaci n S R Menor a 100dB debajo de la salida medida 20Hz 20kHz Circuitos de Protecci n Protecci n de offset de voltaje de salida Protecci n de disipador de calor de so...

Page 15: ...CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN PHONIC CORPORATION...

Page 16: ...16 ICON 300 700 Phonic Icon 300 700 Icon 200v 140v 100v 50v 25v XLR XLR DC 25V 70V 100V 45Hz 1 2 AC 3 Icon 300 700...

Page 17: ...17 ICON 300 700 1 ON OFF LED 2 LED Icon300 700 3 ICON 300 Icon 300 700 4 Icon 300 700 26 dB 5 ICON 700 Icon 700 400W 6 1 2 7 XLR XLR 8 9 XLR XLR ICON 10 1 2 1 off 11 12 25V 70V 100V 140V 200V 0 70 100...

Page 18: ...18 ICON 300 700 8ohms ICON300 1 02Volts 2 4dBu ICON700 1 02Volts 2 4dBu 23v 70v 100v ICON300 700 Mono ICON300 700 MONO 1 2 3 20 300W 240W 25 volt 50 volt...

Page 19: ...volt 1 140 200v 2 3 140 volt 200 volt mono AMP icon 80hms icon300 700 1 4 MaxTop MaxRatedPL 2 MaxRatedPL Impedance 2 MaxTop MaxRatedPL 2ohms Impedance Direct Output Icon700 8ohm Direct Output MaxTop...

Page 20: ...1kHZ 1 THD 420W 850W mono ohm 1kHZ 1 THD 540W 1100W 200V or 140V 300W 700W 100V or 70V 150W 2 350W 2 25V 120W 280W 2 0 2dB 50Hz 50kHz 50Hz 16kHz 0 05 0 05 1 02V 1 02V 28dB 32dB 20k 10k ohm 200 direct...

Page 21: ...21 ICON 300 700 CLIP CLIP ICON 300 BLOCK DIAGRAM DIAGRAMA DE BLOQUE...

Page 22: ...22 ICON 300 700 ICON 700...

Page 23: ...support Ah podr encontrar respuestas a las preguntas m s frecuen tes consejos t cnicos descarga de drivers instruc ciones de devoluci n de equipos y m s informaci n de mucho inter s Nosotros haremos t...

Page 24: ......

Reviews: