background image

1. 

Read  these  instructions  before 

operating 

this 

apparatus.

2.

  Keep these instructions for future reference.

3.  H

eed all warnings to ensure safe operation.

4. 

Follow all instructions provided in this document.

5.  Do not use this apparatus near 

water

 or in locations 

where condensation may occ

ur.

6.  Clean 

only with

 d

ry 

cloth. Do not use aerosol or 

liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block 

any 

of the ventilation 

openings. 

Install 

in accordance with the manufacturer

’s instructions.

8.  Do not install near 

any 

heat sources such as radiators, 

heat 

registers, 

stoves, or other apparatus 

(including 

.

9.

  Do not defeat the 

safety 

purpose of the polarized or 

grounding-type plug. 

A polarized 

plug 

has 

two 

blades 

with one wider than the other

. A 

grounding type plug 

has 

two 

blades and a third 

grounding

 p

rong. 

The 

wide

 

blade or the third 

prong 

is provided for 

your safety

. If 

the provided 

plug 

does not   into 

your 

outlet, consult 

an electrician for replacement of the obsolete outlet.

10. 

Protect  the 

power 

cord  from 

being  walked 

on  or 

pinched 

particularly 

at 

plug, 

convenience receptacles, 

and the point where they exit from the apparatus.

11

Only 

use 

attachments/accessories 

 b

the 

manufacturer.

12. 

Use 

only  with 

a  cart,  stand,  tripod,  bracket,  or 

table 

  b

the  manufacturer,  or  sold 

with

 

the  apparatus.  When  a  cart  is  used,  use  caution 

when  moving 

the 

cart/apparatus

 

combination to avoid 

injury 

from tip

-

over.

13. 

Unplu

g this apparatus during lighting 

storms  or

  w

hen  unused  for  lon

periods of time.

14. 

Refer  all 

servicing 

to 

  service    personnel. 

Servicing 

is 

required when

 the apparatus has been 

damaged 

in 

any way

, such as 

power-supply 

cord or 

plug 

is 

damaged, liquid 

has been spilled or objects 

have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 

normally

, or has been dropped.

IMPOrTaNT SafETY INSTruCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The 

lightning 

flash 

with  arrowhead  symbol,  w

ithin  an 

equilateral  triangle, 

is  intended  to  alert  the  user  to  the 

presence  of  uninsulated  “

dangerous  voltage

” 

within 

the 

product’

 

magnitude to constitute a risk of electric shock to person

s.

The exclamation point 

within 

an 

equilatera

triangle 

is i

n-

tended to alert the user to the presence of important operat

-

ing 

and maintenance 

(servicing

) instructions in the literature 

accompanying the applianc

e.

WarNING: 

To reduce the risk of 

 or electric shock, do 

not expose this apparatus to rain or moisture.

CauTION: 

Use of controls or adjustments or performance 

of  procedures  other  than  those 

  m

ay 

result  in 

hazardous radiation exposure.

The apparatus shall not be exposed to 

dripping

 or 

splashing 

and that no objects 

 

with liquids, 

such as vases, 

shall be placed on the apparatus. The MAINS 

plug

 is used as the disconnect device, the disconnect device shall 

remain readily operable. 

Warning

: the user shall not place this apparatus in the 

 area 

during 

the operation so that the mains 

switch 

can be easily accessible. 

CauTION

rISK Of ElECTrIC ShOCK

DO NOT OPEN

Summary of Contents for ICON300

Page 1: ...User s Manual Manual del Usuario ICON300 ICON700 CONTRACTOR POWER AMPLIFIER AMPLIFICADOR DE POTENCIA PARA CONTRATISTA ICON300 ICON700 English Espa ol...

Page 2: ...ciones 10 Acerca de Este Manual 10 Panel Frontal 11 Panel Trasero 11 Conexiones de Entrada Balanceada de bornes de Seguridad 12 Conexiones de Salida de los Bornes de Seguridad 12 Salidas del Transform...

Page 3: ...hting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug...

Page 4: ...Toroidal output transformers provide full electrical isolation and meet worldwide safety agency approval Built in 45 Hz subsonic filter prevents speaker transformer saturation with minimal effect on...

Page 5: ...s a built in limiter on each channel to prevent clipping Should the signal reach a level high enough to cause clipping ie output power is over 400W per channel the limiter momentarily reduces the inpu...

Page 6: ...type shown are recommended Always make sure the amplifier is turned off before you change any output connections Loose screw terminals insert wire connectors under screws Tighten screw terminals Dire...

Page 7: ...r Panel Description Never parallel the speaker outputs Low Impedance and Distributed Speakers on Icon Amplifiers If your application calls for connection of an 8 ohm speaker and a distributed line to...

Page 8: ...2dB Input Impedance Balanced Unbalanced 20k 10k ohm Damping Factor 200 direct output S N Ratio Less than 100dB below rated output 20Hz 20kHz Protection Circuits Output offset voitage protection Heat s...

Page 9: ......

Page 10: ...Toroidales de salida que proveen de aislamiento el ctrico total y concuerdan con las especificaciones de seguridad internaciones les Filtro subs nico integrado a 45 Hz que previene que los transformad...

Page 11: ...ejem la potencia de salida es de m sde400Wporcanal elimitadorreducir moment neamente el nivel de la se al de entrada solo lo suficiente para prevenir esto El LED de limitaci n se encender cuando esto...

Page 12: ...eg rate de que el amplificador este apagado antes de cambiar cualquier conexi n de salida Liberal los tornillos de las terminales inserta las conexiones de los cables debajo de los tornillos Aprieta f...

Page 13: ...asero Nunca pongas en paralelo las dos salidas Altavoces Distribuidos y de Baja Impedancia en los Ampli ficadores Icon SI tus aplicaciones necesitan la conexi n de altavoces de 8 ohm y una l nea distr...

Page 14: ...tor Damping 200 Salida directa Relaci n S R Menor a 100dB debajo de la salida medida 20Hz 20kHz Circuitos de Protecci n Protecci n de offset de voltaje de salida Protecci n de disipador de calor de so...

Page 15: ...CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN PHONIC CORPORATION...

Page 16: ...16 ICON 300 700 Phonic Icon 300 700 Icon 200v 140v 100v 50v 25v XLR XLR DC 25V 70V 100V 45Hz 1 2 AC 3 Icon 300 700...

Page 17: ...17 ICON 300 700 1 ON OFF LED 2 LED Icon300 700 3 ICON 300 Icon 300 700 4 Icon 300 700 26 dB 5 ICON 700 Icon 700 400W 6 1 2 7 XLR XLR 8 9 XLR XLR ICON 10 1 2 1 off 11 12 25V 70V 100V 140V 200V 0 70 100...

Page 18: ...18 ICON 300 700 8ohms ICON300 1 02Volts 2 4dBu ICON700 1 02Volts 2 4dBu 23v 70v 100v ICON300 700 Mono ICON300 700 MONO 1 2 3 20 300W 240W 25 volt 50 volt...

Page 19: ...volt 1 140 200v 2 3 140 volt 200 volt mono AMP icon 80hms icon300 700 1 4 MaxTop MaxRatedPL 2 MaxRatedPL Impedance 2 MaxTop MaxRatedPL 2ohms Impedance Direct Output Icon700 8ohm Direct Output MaxTop...

Page 20: ...1kHZ 1 THD 420W 850W mono ohm 1kHZ 1 THD 540W 1100W 200V or 140V 300W 700W 100V or 70V 150W 2 350W 2 25V 120W 280W 2 0 2dB 50Hz 50kHz 50Hz 16kHz 0 05 0 05 1 02V 1 02V 28dB 32dB 20k 10k ohm 200 direct...

Page 21: ...21 ICON 300 700 CLIP CLIP ICON 300 BLOCK DIAGRAM DIAGRAMA DE BLOQUE...

Page 22: ...22 ICON 300 700 ICON 700...

Page 23: ...support Ah podr encontrar respuestas a las preguntas m s frecuen tes consejos t cnicos descarga de drivers instruc ciones de devoluci n de equipos y m s informaci n de mucho inter s Nosotros haremos t...

Page 24: ......

Reviews: