  Front view                                      Back view 

  

      

 

 

Item 

Description 

LCD 

Display temperature and working status. 

MODE button 

Access to user and engineer menu and for setting 
confirmation or change 

/

 unit if press for over 3 sec. 

FAN button 

Toggle to change Fan mode: Auto or cont. Low/ Hi 

UP & DOWN buttons 

Increase & decrease setting or previous/next item 

SET button 

Setting for schedules and Timers 

On/Off button 

Turn on/ off thermostat 

Set-point icons 

Displaying set-point temperature while it is flashing 

Fan icons 

Indicate Fan status 

Snow Flake icon 

Indicate working on Cooling mode; Flashing = Pre-wet 

10 

Hot spring icon 

Indicate working on Heating mode  (NA) 

11 

Flow icon 

Indicate working on ventilating mode 

12 

Gear icon 

Indicate cooler is ON 

13 

Clock 

Indicate current System ON or OFF was enabled by real 
time Timer. 

14 

Sleep 

(NA) 

15 

Moon Sign 

Indicating room is unoccupied or Vacation Mode 

16 

Outdoor icon 

Indicating door/ window is open(NA) 

17 

Cover screw 

Screw to tighten back cover with front cover 

18 

Back plate 

Plate for mounting on electric box 

19 

Wiring terminal blocks 

Terminals for wiring 

20 

Mounting holes 

Holes for mounting on electric box 

21 

Clock 

Display time  

22 

Schedule number 

Current Schedule running or setting 

23 

Day 

Current day of Sunday ~ Saturday or setting 

24 

Sun 

Indicate Drain is undergoing now 

Summary of Contents for Pro-V Series

Page 1: ...NSTALLATION 3 MOUNTING ON ELECTRIC BOX 3 MOUNTING FRONT COVER 3 WIRING EXAMPLE 3 OPERATION 4 SETTING CLOCK 7 SETTING PROGRAM FUNCTION 7 Phoenix Manufacturing Inc 3655 E Roeser Rd Phoenix AZ 85040 602...

Page 2: ...ng on Cooling mode Flashing Pre wet 10 Hot spring icon Indicate working on Heating mode NA 11 Flow icon Indicate working on ventilating mode 12 Gear icon Indicate cooler is ON 13 Clock Indicate curren...

Page 3: ...tric box by tightening the back plate screws Suggest using Philips drive truss head or washer head 6 32x 3 4 20mm 4 DO NOT let the bolt head rise above the wall of mounting holes of back plate It migh...

Page 4: ...cription Remarks 1 Normal Display Display current room or set point temperature and current time day Setting SP parameter in Engineer table to choose Current room or Set point temperature 2 Temperatur...

Page 5: ...5 Fig 2 User Mode operation sequence...

Page 6: ...6 1 Detailed State Diagram for Clock Setting...

Page 7: ...7 2 Detailed State Diagram for Schedule Setting Press Mode button to select day shows steadily deselect day flash Press Up Down button to other day for multiple choice...

Page 8: ...29 5 8 00 Cool 85 0 29 5 8 00 Cool 85 0 29 5 8 00 Cool 85 0 29 5 8 00 Cool 85 0 29 5 8 00 Cool 85 0 29 5 Sch 3 18 00 Cool 79 0 26 0 18 00 Cool 79 0 26 0 18 00 Cool 79 0 26 0 18 00 Cool 79 0 26 0 18 0...

Page 9: ...in action Pre wet might be postponed until drain action finished 3 Drain Action 1 Automatic Drain Every accumulative 4 hours default and 2 4 6 8 or 0 OFF hours selectable of cooler pump operation will...

Page 10: ...g Heating to be ESIC ESIH refer to Engineer table for details When the contact is deactivated Room back to be occupied it will set the set point values back as normal 2 If disable local ESI contact de...