background image

Voltage Output Mode: 

 Voltage Output Mode

 is used to adjust the output voltage the PSU reverts

to after the platter has reached operating speed.  The motor requires much more torque at start up
than it does once the platter is on speed;  by reducing the running voltage once the platter is moving,
vibration and noise are greatly reduced.  The PSU will always assert the maximum output voltage
when starting, or changing speeds, then revert to the programmed lower voltage after approximately
3 seconds. 

 Voltage Output Mode

 has separate adjustments for 33.3 and 45 RPM;  both can be

selected, displayed and adjusted while in 

Voltage Output Mode

.

Enter 

Voltage Output Mode

 from 

Standby Mode

 by holding the  

Minus

 button;  press and release

the 

Stby

 button.  The display will show

:

The display will then indicate the current speed selection (33.3/45.0) and start the turntable motor
rotating.  The display will then show the current reduced output voltage for the selected speed;  range
is  approximately  75%-100%  of  the  maximum  output  voltage:  85-115V  in  1V  steps  for  120V
supplies and 170-230V in 2V steps for 240V supplies.  The following indicates a voltage of 95V
for a 120V supply:

Increase or decrease the output voltage for the selected speed by pressing and releasing the 

Plus

 or

Minus

 buttons until the desired voltage is displayed or measured with a voltmeter.  Pressing and

holding the 

Plus

 or 

Minus

 buttons will automatically increase or decrease the voltage at a rate of

8 times per second.

4

Summary of Contents for Eagle Digital

Page 1: ...Operators Manual Eagle Digital Power Supply Unit...

Page 2: ...tage 115 230V RMS nominal adjustable from 85 to 115VAC and 170 to 230VAC Frequency 60Hz Motors 60 0 Hz 33 3 RPM and 81 0 Hz 45 0 RPM 50Hz Motors 50 0 Hz 33 3 RPM and 67 5 Hz 45 0 RPM Distortion Less t...

Page 3: ...L and into the controller rear panel connector marked AMP Connect the output of the wall adapter to the amplifier by plugging the 2 1mm plug into the connector on the back of the amplifier marked 48VD...

Page 4: ...the appropriate AC signal to the motor The display will show the currently selected speed or offset The amplifier s LED will be Green when the unit exits Standby Mode Soft Start Wheneverthe Eagle PSU...

Page 5: ...r Voltage Output Mode from Standby Mode by holding the Minus button press and release the Stby button The display will show The display will then indicate the current speed selection 33 3 45 0 and sta...

Page 6: ...is fitted with either50Hz or 60 Hz operation As shipped from the factory the Eagle is set for the small spindle extensive testing has shown this to be the most stable option with the least vibration E...

Page 7: ...he display will then show the current speed offset in 0 01 RPM steps range is 0 99 to 0 99 The following indicates an offset of 0 15 RPM Increase or decrease the base frequency offset for the selected...

Page 8: ...ll show Release both buttons and the display will show don to indicate factory default settings have been restored Press and hold the Stby button to return to Standby Mode Factory Default Programming...

Page 9: ...speed on thedisplay and can make micro fine adjustmentsto the output frequency to lock the turntable speed to within 0 005 RPM The adjustment is done slowly and evenly over the entire next revolution...