Frequency  Calibration  Mode: 

Frequency  Calibration  Mode

  is  used  to  fine  tune  the  output

frequency to compensate for belt tension and other variables that may cause the platter to rotate
faster  or  slower  than  the  indicated  speed.   

Frequency  Calibration  Mode

  will  adjust  the  base

frequency  in  0.01RPM  steps  within  a  range  of  ±1.0  RPM.   

Frequency  Calibration  Mode

  has

separate adjustments for 33.3 and 45 RPM;  both can be selected, displayed and adjusted while in

Calibration Mode

.

Enter 

Frequency Calibration Mode

 from 

Standby Mode

 by holding the 

PLUS

 button;  press and

release the 

Stby

 button.  The display will show

:

The display will then indicate the current speed selection (33.3/45.0) and start the turntable motor
rotating.  The display will then show the current speed offset in 0.01 RPM steps;  range is +0.99
to -0.99.   The following indicates an offset of -0.15 RPM:

Increase or decrease the base frequency offset for the selected speed by pressing and releasing the

Plus

 or 

Minus

 buttons until the exact turntable speed is indicated by a strobe device or tachometer.

Pressing and holding the 

Plus

 or 

Minus

 buttons will automatically increase or decrease the speed

at a rate of 8 times per second.

To select the other speed offset, press and release the 

Stby

 button.  The display will show the newly

selected speed, then revert to the offset for that  speed selection.   Increase or decrease the base
frequency offset for the selected speed as above.

When frequency calibration is complete, press and hold the 

Stby

 button;  the display will show

“SAV” and the frequency offsets will be saved in non-volatile memory.  The PSU will then return
to 

Standby Mode

.

6

Summary of Contents for Eagle Digital

Page 1: ...Operators Manual Eagle Digital Power Supply Unit...

Page 2: ...tage 115 230V RMS nominal adjustable from 85 to 115VAC and 170 to 230VAC Frequency 60Hz Motors 60 0 Hz 33 3 RPM and 81 0 Hz 45 0 RPM 50Hz Motors 50 0 Hz 33 3 RPM and 67 5 Hz 45 0 RPM Distortion Less t...

Page 3: ...L and into the controller rear panel connector marked AMP Connect the output of the wall adapter to the amplifier by plugging the 2 1mm plug into the connector on the back of the amplifier marked 48VD...

Page 4: ...the appropriate AC signal to the motor The display will show the currently selected speed or offset The amplifier s LED will be Green when the unit exits Standby Mode Soft Start Wheneverthe Eagle PSU...

Page 5: ...r Voltage Output Mode from Standby Mode by holding the Minus button press and release the Stby button The display will show The display will then indicate the current speed selection 33 3 45 0 and sta...

Page 6: ...is fitted with either50Hz or 60 Hz operation As shipped from the factory the Eagle is set for the small spindle extensive testing has shown this to be the most stable option with the least vibration E...

Page 7: ...he display will then show the current speed offset in 0 01 RPM steps range is 0 99 to 0 99 The following indicates an offset of 0 15 RPM Increase or decrease the base frequency offset for the selected...

Page 8: ...ll show Release both buttons and the display will show don to indicate factory default settings have been restored Press and hold the Stby button to return to Standby Mode Factory Default Programming...

Page 9: ...speed on thedisplay and can make micro fine adjustmentsto the output frequency to lock the turntable speed to within 0 005 RPM The adjustment is done slowly and evenly over the entire next revolution...

Reviews: