background image

To select the other speed output voltage, press and release the 

Stby

 button.  The display will show

the newly selected speed, then revert to the output voltage for that speed selection.  Increase or
decrease the output voltage for the selected speed as above.

When output voltage selections are complete, press and hold the 

Stby

 button;  the display will show

“SAV” and the voltage outputs will be saved in non-volatile memory.  The PSU will then return to

Standby Mode

.

Pulley Select Mode: 

 Pulley Select Mode

 is used to specify which pulley your motor is fitted with

(either 50Hz or 60 Hz operation).  As shipped from the factory, the Eagle is set for the 

small

 spindle;

extensive testing has shown this to be the most stable option with the least vibration.

Enter 

Pulley Select Mode

 by  removing the cable between  the Eagle controller and  the amplfier.

Press and  hold the  

Plus

 button while re-inserting the cable.  The display will show

:

Release the 

Plus

 button and the display will show the currently selected pulley/spindle combination.

Use the 

Plus

 and 

Minus

 buttons to toggle between 50Hz Small and 60Hz Small until the desired

combination is displayed.  Press and hold the 

Stby

 button to save the selection and return to normal

operation.

The 2 selections are displayed as 50Hz Small                     and 60Hz Small                 .

5

Summary of Contents for Eagle Digital

Page 1: ...Operators Manual Eagle Digital Power Supply Unit...

Page 2: ...tage 115 230V RMS nominal adjustable from 85 to 115VAC and 170 to 230VAC Frequency 60Hz Motors 60 0 Hz 33 3 RPM and 81 0 Hz 45 0 RPM 50Hz Motors 50 0 Hz 33 3 RPM and 67 5 Hz 45 0 RPM Distortion Less t...

Page 3: ...L and into the controller rear panel connector marked AMP Connect the output of the wall adapter to the amplifier by plugging the 2 1mm plug into the connector on the back of the amplifier marked 48VD...

Page 4: ...the appropriate AC signal to the motor The display will show the currently selected speed or offset The amplifier s LED will be Green when the unit exits Standby Mode Soft Start Wheneverthe Eagle PSU...

Page 5: ...r Voltage Output Mode from Standby Mode by holding the Minus button press and release the Stby button The display will show The display will then indicate the current speed selection 33 3 45 0 and sta...

Page 6: ...is fitted with either50Hz or 60 Hz operation As shipped from the factory the Eagle is set for the small spindle extensive testing has shown this to be the most stable option with the least vibration E...

Page 7: ...he display will then show the current speed offset in 0 01 RPM steps range is 0 99 to 0 99 The following indicates an offset of 0 15 RPM Increase or decrease the base frequency offset for the selected...

Page 8: ...ll show Release both buttons and the display will show don to indicate factory default settings have been restored Press and hold the Stby button to return to Standby Mode Factory Default Programming...

Page 9: ...speed on thedisplay and can make micro fine adjustmentsto the output frequency to lock the turntable speed to within 0 005 RPM The adjustment is done slowly and evenly over the entire next revolution...