background image

Instruction manual

The newly developed professional active DSP LINE ARRAYS , serie: Digivoice -110.8 DSP2 (8-channels DSP) and serie:
Digivoice-220.16 DSP2 (16-channels DSP), have been developed especially for sound transmission in acoustic difficult 
areas with long reverberation times like such as churches, conference rooms, museums, cathedrals, conference centers 
and halls, but also as the perfect „sound producer“ for multimedia applications.

The active DigiVoice audio systemes consist of software-controlled speakers, each of the 8 resp.16 DSP channels has 
an own  Class-D final stage which are  regulated with different acoustic characteristics to fulfil the acoustic requirements 
of the particular location.

The DSP supported speaker systems allow a precise directive sound and high-precision directivity by a high-quality 
mathematical calculation of the optimal parameters by the DSP (audio signal processor).
Steady volume in the ranges @ 95 dB „NEAR FIELD“ and „WIDE FIELD“ and an excellent speech intelligibility in the 
complete sound range are only some advantages of the DigiVoice serie.

Most important features are the continuous electronical controllability of sound outlet angle and inclination angle 
in vertical direction in real time, without mechanical direction of the speaker systems (incline).

The Digivoice systems provide specific incline adju / -45 degrees) and the vertical sound angle (6 degrees 
to  14 degrees), parameterization is done by the system automatically by the digital DSP control.

Beyond that the integrated DSP audio system offers a whole lot of audio processing functions: 

MAIN CONTROL (basic settings)

- Volume control 

/ volume control 

(-20 dB to +6 dB)

- Delay adjustment (0 to 500 ms)
- Signal limiter with threshold (-40 dB to +6 dB) with mode: SLOW/NORMAL/FAST, adjustment
- Noise gate with LEVEL/ATTACK/RELEASE, adjustment and BYPASS.

DEVICE SETTINGS

- Automatic „SCANNING“ of the IP addresses of all networked DigiVoice speakers.
- Besides that automatic allocation of the COM PORTs with port time out and COM-port display.

BEAM CONTROL (User settings)

- Column elevation / m

ounting height

: (distance of the floor area) with setting parameters 1.5 m to 3 m height.

- Focus distance 

/ beam range

: (directivity length while maintaining the sound pressure) according to model up to 25 meters.

- Focus elevation / b

eam height

: height setting for the acoustic lense in the area of 0.5 to 3 meters.

- Opening angle: width setting for the acoustic lense in the aera of 6 to 14 degrees.

PEQ (parametrical equalizer)

- Selection of up to 10 PEQ elements.

-

 Frequency selection of 20 Hz to 20 kHz.

-

 Range of effects Q-factor of 0.05 to 3 OCT.

-

 Setting of amplification or deadening of the selected frequency of -20 dB to +12 dB.

Useful information

:

A graphic presentation of the modified DSP configuration is integrated in the software under Operating Characteristic 
and Beam Drawing.

GENERAL INORMATION and SYSTEM DESCRIPTION

Summary of Contents for DigiVoice-110.8 DSP2

Page 1: ...d Trademark Office TM All brands are properties of their respective owners DOC 210812 M a d e i n E U DSP supported speaker systems which provide a precise directional sound and high precision directi...

Page 2: ...a way that nobody can step onto it or that it can be jammed This is to apply especially for plugs sockets and the place where the cable comes out of the device 11 Only use equipment and products spec...

Page 3: ...line adjustment 45 degrees and the vertical sound angle 6 degrees to 14 degrees parameterization is done by the system automatically by the digital DSP control Beyond that the integrated DSP audio sys...

Page 4: ...meters are entered into the software ACML CONTROLL 1 5 by the user 1 Mounting height 2 Beam range 3 Beam height 4 Opening angle The parameterization is done by the system via digital DSP control autom...

Page 5: ...ection to a PowerVoice automatic mixer by a system interface Important For the system networking please always use shielded CAT 5 lines 3 100V SIGNAL INPUT JACK Serves for direct connection resp signa...

Page 6: ...optional input to 100V IN DigiVoice 100V speaker line optional input to 100V IN DigiVoice Microphones Copyright 2012 Phoenix Professional Audio GmbH www phoenix pa com The Phoenix logo is registered...

Page 7: ...istered at the German Patent and Trademark Office TM All brands are properties of their respective owners PROGRAMMING SYSTEM CONNECTION VIA INTERFACE XLR XLR symm audio signal connection USB USB conne...

Page 8: ...16 DSP2 serie has been constructed modular and consists of two system components which have to be connected together mechanically and electrically Referring to this first of all please connect the tw...

Page 9: ...e can be installed on the PC After the installation the program ist started automatically After the network connection of all present DigiVoice systemes with D A interface RJ 45 inputs the connection...

Page 10: ...ELAY window you get into the submenu DELAY There is one DELAY available Inputs can be adjusted in ms m and cm Each DigiVoice system can have its own delay setting TIP A minimal signal delay of i e 2 m...

Page 11: ...ction speed of the internal circuitry to the input signal The longer the ATTACK time is chosen the later the limiter effect starts With longer ATTACK times the LIMITER affects more to the average sign...

Page 12: ...es the limiter has more effect to the average signal level and not anymore to fast and high peak levels This causes a softer limiter effect and maintains the sig nal dynamics extensively but cannot av...

Page 13: ...der that the measurement from the floor area has to be done up to the lower housing edge Measure the distance and take the measured value over to the software in the field COLUMN ELEVATION mounting he...

Page 14: ...information The acoustic lense height should if possible adjusted to the height of the audience ear level SOFTWARE FIELD BEAM CONTROL OPENING ANGLE In the field OPENING ANGLE the required vertical sou...

Page 15: ...s you have to make a room adjustment resp a room equalization after the installation To carry out a room measurement you need a measuring tool Minimum is therefor the NiniLink Acoustilyzer from Neutri...

Page 16: ...the transmission curve has the strongest peak This can be damped by the power in the voice amplifier integrated limiter and automatic feedback in Digivoice systems by correcting with PEQ as follows Fi...

Page 17: ...le H 130 degrees 6dB 1kHz 8kHz Sound angle V 6 degrees to 14 degrees setting DSP SOFTWARE Input sensitivity 0dB on XLR interface or 50dB 100V signal IN Phoenix jack Input impedance LINE 15 kOhm 100V 4...

Page 18: ...gle H 130 degrees 6dB 1kHz 8kHz Sound angle V 6 degrees to 14 degrees setting DSP SOFTWARE Input sensitivity 0dB at XLR interface or 50dB 100V signal IN Phoenix jack Input impedance LINE 15 kOhm 100V...

Page 19: ...res Special powder coatings according to the RAL numbers are possible on request It can be said that the new DigiVoice systems have a top design in the range audio speakers due to their technical poss...

Page 20: ...Instruction manual NOTES...

Reviews: