6. Product information
35
De
utsch
English
6.1 Mode of operation
The
RK
Multi
lift
lifting column works exclusively as a height-adjustable ceiling holder for e.g. monitors or
touch panels. It is driven by a DC motor.
6.2 Technical data
6.2.1 Technical specifications Multilift II safety
Multilift II safety
Floor area
312 x 90 mm (L x W)
Installation height
Lifting range + 203 mm
Stroke
355 mm, 400 mm, 452 mm, 498 mm
Weight
Basic weight: 5.27 kg + (0.017 kg/mm * Lifting range)
Supply voltage (primary)
24 V DC - 32 V DC
Protection class
III
Electrical connection
Mini-Fit Jr., 8-pin
Max. power input
4.0 A at U = 24 V DC
max. power consumption
120 W
Duty cycle (ED)
ED: S3 10 %
Lifetime
10000 double strokes with a stroke of 500 mm
Protection class
IP 20
Continuous sound pressure level
less than 60 dBA
Lifting speed
16 mm/s
Max. tensile force
600 N
Position signal
(Cancellation Hall sensor)
Increments per mm travel:
6.5 per channel
Transport and storage conditions
Temperatures from -20 deg. C to +60 deg. C, relative humidity 30 per cent to 85 per
cent (no thawing), air pressure 700 hPA to 1060 hPA
Operating conditions
In dry rooms at temperatures from +5 deg. C to +40 deg. C, relative humidity from
30 per cent to 75 per cent (no thawing), air pressure 700 hPA to 1060 hPA (up to an
altitude of 3000 m)