background image

 

 

 

 

Safety 

5.1 

Safety instructions 

 
Phoenix  Mecano  Komponenten  AG  has  constructed  this  electric  cylinder  according  to  the  current  state  of  the  art  and  existing  safety 
regulations. However, if the electric cylinder is misused and/or operated in the manner inconsistent with the intended use or if the safety 
instructions are not observed, this may result in hazards to personnel and property. Competent handling guarantees high performance 
and availability of the electric cylinder. Faults or conditions, which may impair the safety, must be rectified immediately. 
 
Every person involved in the assembly, use or operation of this electric cylinder, must have read and understood the assembly instructions. 
 
This includes: 

 

understanding the safety instructions in the text, and 

 

being familiar with the configuration and functioning of various options of operation and application. 

 
The electric cylinder may only be used, installed and operated by the designated, trained personnel. Any works on and with the electric 
cylinder may only be carried out according to this instruction. This instruction needs therefore be kept safe and close at hand in the vicinity 
of the electric cylinder. 
 
The general, national or operational safety instructions shall be observed. Responsibilities for the  use, installation and operation of this 
electric cylinder must be unequivocally stipulated and observed so that no unclear situation may arise with regard to safety aspects. Before 
every commissioning, the user must ensure that no persons or objects remain in the danger area of the electric cylinder. The user may 
only operate the electric cylinder if it is in a faultless condition. Any change must be immediately reported to the nearest person responsible. 

5.2 

Special safety instructions 

 

 

Any works with the electric cylinder may only be carried out according to this instruction. 

 

The device may only be opened (installed / dismantled) by authorised specialist personnel. In case of any defect of the electric 
cylinder, we recommend to contact the manufacturer and/or send this electric cylinder for repair. 

 

Power supply must be disconnected before installation, dismantling, maintenance or troubleshooting. 

 

The re-user must prevent pinching between guiding tube and the front suspension by means of design. 

 

A proper installation of the supply lines prevents the hazards posed by this application. 

 

Only use original accessories and spare parts. 

 

The re-user must prevent potential damages caused by the failure of the end position switch-off or nut breakage by means of 
design. 

 

The electric cylinder may not be exposed to lateral forces or torques. 

 

Only use suitable screws (no shoulder screws). Note the hole- Ø of the cylinder mounts! 

 

Tighten the screws so firmly that they cannot loosen - but not too tight, as otherwise high forces would act on the mounts and 
safe  operation  would  no  longer  be  ensured!  The  drive  must  be  freely  rotatable  in  the  suspensions  -  tension  would  result  in 
immediate destruction of the drive! 

 

Loss of connection between the thrust rod and guiding tube in case of a tensile load must be prevented by means of design. It 
means that, especially with suspended loads, additional safety devices (e.g.: cable, chain, etc.) must be affixed!  

 

During maintenance, only original parts must be used and installed by trained specialist personnel. 

 

For safety reasons, unauthorised modifications or changes of the electric cylinder are prohibited. 

 

The performance data of this electric cylinder determined by Phoenix Mecano Komponenten AG may not be exceeded (see 6.6 

Performance diagram

). 

 

The type plate must remain legible. The data must be retrievable without effort at any time. 

 

Safety-relevant hazard signs identify danger areas on the product. 

 

Safety-relevant devices must be tested for operability, damage and integrity on a regular basis, at least once a year. 

 

In case of an overhead installation of the electric cylinder, the fastened loads  must be secured onsite against dropping. The 
danger area under the application must be marked in the documentation of the final product. 

 

The electric cylinder must immediately be put out of operation if the mains cable and/or supply line is damaged. 

 

Higher-level safety circuits (emergency stop, etc.) are required for safe operation of the electric cylinders and must be provided 
and installed on site by the subsequent user / user. 

 

 

Summary of Contents for LD75E+P

Page 1: ...EN Assembly Instruction Linear actuator LD75E P 2 B 017 663 Version 1 2...

Page 2: ...8 5 1 Safety instructions 8 5 2 Special safety instructions 8 5 3 Safety signs 9 6 Product information 10 6 1 Mode of operation 10 6 1 1 Variants of power supply 10 6 1 2 Variants of force speed 10 6...

Page 3: ...mponenten AG 3 7 2 Transport and storage 21 7 3 Important information on installation and commissioning 21 7 4 Assembly 22 7 4 1 Installation procedure 23 7 5 Maintenance 24 7 6 Cleaning 24 7 7 Dispos...

Page 4: ...n Parliament and the Council dd 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment IEC 60601 1 2 2014 Medical Electrical Equipment Part 1...

Page 5: ...e This assembly instructions help avoid hazards and downtime and guarantee and or extend the lifetime of the product Hazard warnings safety recommendations and data in these assembly instructions shal...

Page 6: ...tments to the current version of the electric cylinder In case of any inquiries please specify the type plate data Our address Phoenix Mecano Komponenten AG Hofwisenstrasse 6 CH 8260 Stein am Rhein Te...

Page 7: ...nintended use and is forbidden Phoenix Mecano Kompo nenten AG is released of liability and general operating licence of this electric cylinder becomes void in case of unintended use 4 3 Reasonably for...

Page 8: ...r for repair Power supply must be disconnected before installation dismantling maintenance or troubleshooting The re user must prevent pinching between guiding tube and the front suspension by means o...

Page 9: ...ylinder must be complied with while non ob servance increases the risk of an accident The General mandatory action sign indicates the necessity to exercise caution Data marked with this sign in these...

Page 10: ...4 mm s 21 mm s Execution 4 12 VDC 300 N 300 N 160 N 150 N 48 mm s 39 mm s Execution 5 24 VDC 750 N 750 N 750 N 400 N 15 mm s 13 mm s Execution 6 24 VDC 750 N 750 N 750 N 400 N 25 mm s 19 mm s Executio...

Page 11: ...Phoenix Mecano Komponenten AG 11 6 2 Dimensions of geometry...

Page 12: ...12 6 3 Variants of suspension Option 1 0 Option 2 90 The rear view of the drive is shown in the top picture and the front view in the bottom picture...

Page 13: ...perating voltage 12 VDC max 6 A 24 VDC max 4 A Ambient temperature 40 C to 85 C Operating temperature 20 C to 65 C full power 5 C to 40 C Self locking Yes depending on gear ratio and spindle pitch Str...

Page 14: ...rder to guarantee a high IP protection class we recommend that the free cable end is laid and connected in such a way that it is inside a protected area e g junction box switch cabinet machine enclosu...

Page 15: ...Phoenix Mecano Komponenten AG 15 6 6 1 Assembly disassembly of the connection cable with plug...

Page 16: ...e polarity potentiometer Switch off at limit in retracted extended position potentiometer connections brought out as a position feedback 6 6 2 Connection diagram for variant 1 AP 4 017 661 supply volt...

Page 17: ...nnect This line must not be connected Black BK Violet VT Yellow YE White WH Green GN 6 6 3 Connection diagram for variant 2 AP 4 017 662 Supply voltage polarity 100 and 130mm potentiometer Kabel skizz...

Page 18: ...ue position signal Depending on the execution you can re solve a stroke of 100 or 130mm Red Plus e g 12V Black Minus Violet Output signal Electrical values Potentiometer RP 10k Series resistance RS 1k...

Page 19: ...Phoenix Mecano Komponenten AG 19 6 7 Performance charts Execution1 Execution2 Execution3 Execution4...

Page 20: ...er optimal conditions stabilised power source and room temperature These values may vary due to components which are subject to tolerances such as the leading spindle guide nut and gear wheels as well...

Page 21: ...ric cylinder and or other components damaged It is essential to implement an emergency stop onsite which could interrupt reliably the operating voltage in the event of a failure or malfunction of the...

Page 22: ...urning rotation of the pushrod or the fixed swivel head is equal to an adjustment of the end positions Attention The attachment points for installation of the electric cylinder must be aligned flawles...

Page 23: ...n the direction of the arrow see figure 2 Fix the suspension at the front Attention The counterpart piece may not be able to rotate The electric cylinder must be able to be rotated in the direction of...

Page 24: ...the electric cylinder are prohibited Safety related devices must be tested on a regular basis depending on the frequency of use however at least once a year for integrity and operability 7 6 Cleaning...

Reviews: