EV Charge Control Basic
56 / 68
PHOENIX CONTACT
106377_en_04
Hold
-
ing
4002
16 bits Read/write Retentive
Activating the locking function
Charging connector in the In
-
frastructure Socket Outlet
Integer
If S1/DIP 3 = OFF:
0: Locking is performed automat
-
ically when the vehicle is con
-
nected (status B), unlocking is
performed if the vehicle is not de
-
tected (status A).
(Default, if S1/DIP 3 = OFF, other
values have no effect)
If S1/DIP 3 = ON:
1: Locking upon ON signal at
input ML, unlocking if signal at
input ML = OFF
(Default, if S1/DIP 3 = ON)
2: Locking in the event of a
pulsed signal at input ML, unlock
-
ing upon next pulse
3: Locking if value 1 is written to
register 20002. Unlocking if
value 0 is written.
4006
16 bits Read/write Retentive
Function activation for
charging contactor monitor
-
ing. For charging contactor
monitoring via input CCR,
charging current adaptation
via input CCR must be deacti
-
vated (register 4012 = 0)
Integer
0: Charging contactor monitoring
deactivated (default)
1: Charging contactor monitoring
by evaluating a force-guided N/C
contact at input CCR
4007
16 bits Read/write Retentive
Delay time between switching
off the charging contactor and
executing charging contactor
monitoring
Integer in ms
Default = 200 ms
4008
16 bits Read
–
Rejecting invalid charging
cable
Relevant for EV-CC-AC1-M3-
CBC-... only
Integer
If S1/DIP 4 = OFF
0: All charging cables permitted
If S1/DIP 4 = ON
1: 13 A charging cable is rejected
Table 9
-
2
Register assignment
Type
Address Value
Access
Memory
Function
Coding
Summary of Contents for EV Charge Control Basic
Page 1: ...User manual EV Charge Control Basic Installing and starting up the charging controller ...
Page 14: ...EV Charge Control Basic 14 68 PHOENIX CONTACT 106377_en_04 ...
Page 34: ...EV Charge Control Basic 34 68 PHOENIX CONTACT 106377_en_04 ...
Page 46: ...EV Charge Control Basic 46 68 PHOENIX CONTACT 106377_en_04 ...
Page 69: ......