![Phoenix Contact EV Charge Control Basic User Manual Download Page 10](http://html.mh-extra.com/html/phoenix-contact/ev-charge-control-basic/ev-charge-control-basic_user-manual_1551421010.webp)
EV Charge Control Basic
10 / 68
PHOENIX CONTACT
106377_en_04
For further information on the configuration options for the digital inputs and outputs,
“Modbus description” on page 53
3
LO-
Locking
Control of the locking actuator
†
LO+
LD2
Lock Detection
Digital input, for connecting the locking confirmation, can be configured
LD1
PP
Proximity Plug
Test signal
Current carrying capacity of the connected
charging connector and charging cable ac
-
cording to
IEC 61851-1
CP
Control Pilot
Pilot wire signal
Communication between charging station and
vehicle according to IEC 61851-1, SAE J1772
and GB/T 18487.1
4
SG
Signal Ground
Ground signal for the RS-485 communication interface
B
RS-485
Communication interface
A
5
C2
Contactor
Relay output, charging contactor
Switches the mains voltage to the vehicle via an
external
charging contactor when status C or D is reached
and
the enabled inputs and registers are active.
C1
*
Not protected against overload
†
Not for EV-CC-AC1-M3-CC-...
Table 2
-
1
Connections [...]
No. Name Meaning
Description
Summary of Contents for EV Charge Control Basic
Page 1: ...User manual EV Charge Control Basic Installing and starting up the charging controller ...
Page 14: ...EV Charge Control Basic 14 68 PHOENIX CONTACT 106377_en_04 ...
Page 34: ...EV Charge Control Basic 34 68 PHOENIX CONTACT 106377_en_04 ...
Page 46: ...EV Charge Control Basic 46 68 PHOENIX CONTACT 106377_en_04 ...
Page 69: ......