EV Charge Control Basic
32 / 68
PHOENIX CONTACT
106377_en_04
Connection of high-power loads (e.g., lamps)
– The output stages are supplied with the required voltage of 5 V DC to 30 V DC maxi
-
mum via voltage input 12Va.
– In status 0 (OFF), the outputs are connected to GND and in status 1 (ON,) they are con
-
nected to the potential of 12Va.
– GND is connected to PE internally.
– Please observe the maximum current capacity of 600 mA per output.
Figure 6
-
2
Output circuit with lamps
Connection of loads with low current consumption (e.g., LEDs)
– The output stages are supplied with the required voltage of 12 V DC from voltage output
12V via voltage input 12Va.
– Voltage output 12V can carry a maximum of 500 mA.
– In status 0, the outputs are connected to GND and in status 1, they are connected to
12Va.
GND is connected to PE internally.
Figure 6
-
3
Output circuit with LEDs
Power
L
N
PE
IO
GND
12 V
12 V a
EN
XR
ML
CCR
IN
OUT
ERR
CHG
CON
GND
+5 V DC ... +
3
0 V DC
OUT ERR
CHG CON
Power
L
N
PE
IO
GND
12 V
12 V a
EN
XR
ML
CCR
IN
OUT
ERR
CHG
CON
GND
OUT ERR
CHG CON
Summary of Contents for EV Charge Control Basic
Page 1: ...User manual EV Charge Control Basic Installing and starting up the charging controller ...
Page 14: ...EV Charge Control Basic 14 68 PHOENIX CONTACT 106377_en_04 ...
Page 34: ...EV Charge Control Basic 34 68 PHOENIX CONTACT 106377_en_04 ...
Page 46: ...EV Charge Control Basic 46 68 PHOENIX CONTACT 106377_en_04 ...
Page 69: ......