Page 24
5.5.2.4 Hysteresis for Alarm 2
Set switching on hysteresis
∆
a for Alarm 2
Menu <–> Selection
Select digit
Set digit
Set switching off hysteresis
∆
b for Alarm 2
Menu <–> Selection
Select digit
Set digit
Chapter 5.5.2.6 select signal for output 2
➱
5.5.2.5 Reset Latch signal at Output 2
Menu <–> Selection
Manual reset with red key
Alarm output can only be reset manually if
,
or
is selected.. If
is selected as the function and is dis-
played, then the alarm output can only be reset manually if the totalizer reset
parameter "rESEt" has been programmed for "no.rES" or "EL.rE" .
Electrical reset with MPI-Input
Alarm output can only be reset electrically, if
,
or
is selected as the function and is displayed.
If
is selected as the function and is displayed, then the alarm out-
put can only be reset electrically if the totalizer reset parameter
a
has been programmed as
.
Note: The Display Hold funktion is off.
Both, manual and electrical reset
Alarm output can either be reset manually via the red key or via a reset pulse
on the MP input. If
is selected as the function and is displayed,
then the alarm output can only be reset manually and/or electrically if the to-
talizer reset parameter
is programmed as
.
Note: The Display Hold function is off.
press the
key
to accept
press key
to accept
press the
key to accept the selection
Page 25
5.5.2.6 Select signal form for output 2
Menu <–> Selection
Positiv output signal
Output is activated, when the instantaneous
value > limit 1
Negativ output signal
Output is deactivated, when the instantaneous
value > limit 1.
5.6 MIN/MAX value acquisition
The maximum value may be captured, saved and consulted during operation
by pressing a key.
5.6.1 Capture of MIN/MAX Values
Menu <–> Selection
Example: Yes
Not monitored
Chapter 5.6.2 ,
25
Monitored and saved.
➱
5.6.1.1 Reset Maximum value
Menu <–> Selection
Example: Yes
not resettable
Resettable via the
key .
The MAX value can only be cleared by pressing the red key. In addition
"MAX" must be selected as the display source. In parameter set-up "r.MAX"
must be programmed as "YES"
5.6.2 MIN Value Monitor
Menu <–> Selection
Example: Yes
Not monitored
Chapter 5.7 ,
26
Monitored and saved.
➱
press the
key to
accept
press the
key to accept the selection
english
press the
key to
accept
press the
key to accept the selection