26
Remove the screws from the strain relief
and take off the strain relief bridges.
Mount the controller to the wall with
screws that fit to the wall material. Use
screws with 4 to 5 mm shaft and max.
9 mm head diameter, no counter sink.
Mind that the screws have to carry also
the force applied by the wiring.
Mind also the minimum required
distance to floor and ceiling, this is
necessary for ventilation reasons.
A DIN Rail mounting plate is available
as an accessory (CX-DR2). This allows
mounting the controller on a standard
35mm DIN rail. Use the screws supplied
with the mounting plate to fix it to the
controller.