100-240VAC, 6A - 2.5A, 50-60 Hz

sPDS-480ca 24V

ITEM# 109-000026-00

8

7

6

5

sPDS-480ca 24V

1

2

3

4

POWER/DATA

24VDC

Ethernet

to Ethernet Switch

IEC Power Inlet 
and US Cable set

Fixture Leader Cables

Power Switch

Onboard Push-button Controls

Menu LCD

Ordering Information

 Use Item Number when ordering in North America.

Item

Item Number

Philips 12NC

sPDS-480ca 7.5 V

109-000022-00

910503700107

sPDS-480ca 24 V

109-000026-00

910503700110

Speci

fi

 cations 

Due to continuous improvements and innovations, specifications may change without notice.

Item

Speci

fi

 cation

Details

Electrical

Input Voltage

100 – 240 VAC, auto-switching, 50 / 60 Hz 

Maximum Input Current

6 A at 100 VAC, 5 A at 120 VAC, 2.5 A at 240 VAC

Power 
Output

sPDS-480ca 7.5 V

7.5 VDC, 480 W  (30 W per power port)

sPDS-480ca 24 V

24 VDC, 480 W  (60 W per power port)

Fuse 
Rating

sPDS-480ca 7.5

(16) 5 A, 125 V, 5 x 20 fast blow fuses

sPDS-480ca 24 V

(8) 4 A, 125 V, 5 x 20 fast blow fuses

Physical

Dimensions

(Height x Width x Depth)

3.5 x 19 x 18 in  (89 x 483 x 457 mm)

Weight

26.5 lb  (12 kg)

Construction

2U rack and surface-mountable chassis

Finish

Black matte

Connectors

Data

RJ45 input connector

Power Output

sPDS-480ca 7.5 V

(8) 4-pin output receptacles

sPDS-480ca 24 V

(16) 4-pin output receptacles

Power Input

IEC 320 receptacle type C13, locking clamp

Temperature Ranges

14° – 122° F  (-10° – 50° C) Operating
14°  –  122° F  (-10° –  50° C) Startup
-40°  –  176° F  (-40° –  80° C) Storage

Humidity

0 – 95%, non-condensing

Cooling

Air cooled. (2) speed-con

fi

 gurable fans, with 

serviceable air 

fi

 lters

Air

fl

 ow

Front panel input, back panel output

Heat Dissipation

25% of total power input

Data Input Source

Philips full range of Ethernet controllers, or third-
party KiNET-compatible

*

 Ethernet controllers

Certi

fi

 cation 

and Safety

Certi

fi

 cation

UL / cUL, CE, PSE

Classi

fi

 cation

UL Class 2 power supply

Environment

Dry Location, IP20

19.0 in

sPDS-480ca 24V

Ethernet

(483 mm)

1.8 in

(46 mm)

3.5 in

(89 mm)

16.4 in

(417 mm)

18.0 in

(457 mm)

17.0 in

(432 mm)

Dimensions: Rack Mount Configuration

sPDS-480ca 24V

Ethernet

19.0 in

(483 mm)

18.4 in

(467 mm)

12.3 in

(312 mm)

10.6 in

(269 mm)

1.8 in

(46 mm)

2.9 in

(74 mm)

10.6 in

(269 mm)

13.5 in

(343 mm)

3.0 in

(76 mm)

2.3 in

(58mm)

Dimensions: Surface Mount Configuration

*

 

KiNET is the Ethernet lighting protocol from Philips Color Kinetics. 

Included in the box

sPDS-480ca power / data supply
(2) Rack mount bracket and handles

(2) Surface mount brackets 

(8) Screws, 0.7 X 10 mm

(8) Lock washers

100 VAC 

T

VAC  

50Hz-60Hz, 8A Max.

LISTED
78GF

POWER/D ATA

7.5VDC

sPDS-480ca 7.5V

ITEM# 109-000022-00

12

11

10

9

8

7

6

5

4

3

2

1

13

14

15

16

sPDS-480ca 24 V

sPDS-480ca 7.5 V

Summary of Contents for sPDS-480ca

Page 1: ...sPDS 480ca Power data supply for large scale Ethernet installations ...

Page 2: ...ftware sPDS 480ca features a backlit LCD for easy menu viewing Housed in a 2U rack mountable enclosure sPDS 480ca includes rack handles and surface mount brackets for versatile mounting options Over temperature detection and selectable shutdown options protect sPDS 480ca against operation beyond its rated temperature specification Variable speed fans keep noise levels low and include user servicea...

Page 3: ... V 8 4 pin output receptacles sPDS 480ca 24 V 16 4 pin output receptacles Power Input IEC 320 receptacle type C13 locking clamp Temperature Ranges 14 122 F 10 50 C Operating 14 122 F 10 50 C Startup 40 176 F 40 80 C Storage Humidity 0 95 non condensing Cooling Air cooled 2 speed configurable fans with serviceable air filters Airflow Front panel input back panel output Heat Dissipation 25 of total ...

Page 4: ...uration sPDS 480ca is designed for use in Ethernet networks Typical Ethernet installations with Philips Color Kinetics LED fixtures include an Ethernet switch an Ethernet controller such as Light System Manager or Video System Manager Pro Ethernet Controller Keypads for light show triggering and one or more sPDS 480ca devices In an Ethernet environment each Philips Color Kinetics power data supply...

Page 5: ...cluded IEC power cable CAT 5e or better data cable as required You must also have access to a dedicated Ethernet network an Ethernet switch and a controller that is compatible with a KiNET based lighting system such as Philips Color Kinetics Light System Manager Video System Manager Pro or ColorDial Pro Inspect sPDS 480ca and Accessories Carefully inspect the box containing the sPDS 480ca and the ...

Page 6: ...r brackets for surface mounting 2 Using two included screws and lock washers for each bracket attach two mounting brackets to each side of the device The portion of each bracket with four holes should be flush with the bottom of the device 2 Each of the included mounting brackets mount to the surface using 4 screws each Mount the device to the surface using 16 screws that are suitable for the moun...

Page 7: ...r cables or Flex strands to an available port on the back of the device Ports are labeled 1 through 8 2 Power the device ON Note that before you can control the connected fixtures you must discover fixtures using either the sPDS 480ca device s on board menu described in the next section QuickPlay Pro software or the discover functionality in the software for Light System Manager or Video System Ma...

Page 8: ... the device s LCD backlight Medium Dim Auto Dim Dims the LCD backlight when no buttons have been pressed for 15 seconds Restore Defaults Press Select Restores factory default settings for LCD Backlight Fan Settings and Thermal Settings Network configuration is unaffected Test Test Lights All Off Turns off all nodes All Red Turns on all channels of a particular color All Green All Blue All White Ra...

Page 9: ...of the next two fields as necessary 7 Press Select Press Select again to confirm changes Testing The test commands verify that the device its connected fixtures and cooling fans are operating properly To test lights and fans 1 Press Select to activate the sPDS 480ca menu 2 Select Test The first test command turns all lights off 3 Press the Down button If you have RGB fixtures the All Red test comm...

Page 10: ...se the Up and Down buttons to find the desired thermal setting then press Select Cleaning the sPDS 480ca Air Intake Filter To prevent overheating inspect the air intake filter regularly and clean as needed The air intake filters are located behind the device s front faceplate 1 Disconnect line power from the device 2 Using a Phillips screwdriver loosen the four captive screws on the front of the d...

Page 11: ...nscrew the two screws holding the cover in place Lift the back side of the cover first then remove it 3 Remove the blown fuse from its metal clips The blown fuse is adjacent to the port of the fixtures that failed 4 Replace the fuse with a new identically rated fuse 5 Replace the cover and screws to close the fuse box Device Number of Fuses Replacement Fuse sPDS 480ca 7 5 V 16 5 A 125 V 5 x 20 fas...

Page 12: ...d Powercore are either registered trademarks or trademarks of Philips Solid State Lighting Solutions Inc in the United States and or other countries All other brand or product names are trademarks or registered trademarks of their respective owners Due to continuous improvements and innovations specifications may change without notice Philips Color Kinetics 3 Burlington Woods Drive Burlington Mass...

Reviews: