background image

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 a Philips Group

Section 1/Folio A10-15

Job Information  

Type:

-

Lightolier is a Philips group brand

GO2  

GOS2G217 or 2U

Page 2 of 2

2' x 2' Recessed Fluorescent, High Performance Louver

Static or Air Supply/Return, 2 Lamp T8 or 2U

Options/Accessories

Plaster Frame

: Catalog Number: 

PF22

.

Radio Interference Filter

:  To order one RIF per fixture;  SUFFIX: 

R

To order one RIF per ballast;  SUFFIX: 

B

.

Fusing

: Internal fast-blow fusing. SUFFIX 

A

.  Internal slow-blow fusing.  SUFFIX 

C

.

Electrical Wiring Options

: Consult  factory.

Air Closure Strip

: SUFFIX: 

ACS4

(factory installed).

Drywall Kit

: Order Catalog Number: 

FK92X2

. (Request Folio OA30-10 Rev. A).

Chicago Plenum

: SUFFIX: 

C

.

Specifications

Performance

: In an installation of 2 lamp T8U luminaries in a room cavity ratio of 1,

reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .84. 

Air Handling

(GOA only) side air passages for air supply or air return. Optional side closure strips.

Air return is also provided through the lamp compartment through fixture body ends.

Specifications (continued)

Materials

Chassis parts

are die-formed code gauge cold rolled steel. S ide rails hemmed over and housing ends

turned-in for safe handling. 

Reflector

is 94% reflective aluminum.

Finish

Chassis exterior

–black baked polyester enamel. 

Cavity

–white baked polyester enamel. Rust preven-

tative undercoating. 

Louver

–94% reflective flat white powder coat.

Electrical

: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use

wire suitable for at least 90°.

Labels

: I.B.E.W. UL and ULc Listed.

This product may have a mercury containing lamp. 

Manage in accord with Disposal Laws. See: www.lamprecycle.org

GO2 Series

Body Style:

A

=Air Supply

S

=Static

2

Fixture

Width

2

Lamp

Quantity

Options:

Add appropriate suffix

to catalog no., ie: (C)

Ballast Type:

Ballast

<

10THD         Factor

1-2 Lamp Elec. T8

H

I

*

.88

Advance Optanium

C5*

.77

Advance Optanium

CO*

1.23

LOL Dimming

PS

*Instant Start Standard

Ordering Information

Explanation of Catalog Number. Example: GOS2G22UUNVC5

Ceiling Type:

G

= Grid

(lay-in T bar)

T

= Slot grid or

two-directional 
concealed T 
(see options)

Voltage:

120, 277 or

UNV

=120-277

Lamp Type/

Fixture Length:

17

= 2' T8

2U

= 2' U T8

(Nominal 24")

GO

Standard GO2

GC

For NYC Code – I.B.E.W. Manufactured

GN

For NYC Code – Local 3 Manufactured

5½" Deep Body

0.0

45.0

90.0

FLUX

0

1646

1646

1646

5

1644

1691

1720

162

15

1528

1721

1814

481

25

1341

1628

1864

750

35

1111

1477

1833

925

45

838

1239

1355

899

55

561

779

775

651

65

322

359

202

318

75

165

172

156

174

85

46

47

47

53

90

8

7

4

Model No. GOS2G22UUNVC5

LER = FP - 73.9      IW - 46.0      BF - 0.77

Comparative yearly lighting energy cost per

1000 lumens = $3.25?

Report Number: G2008126

Catalog Number: GOS2G22UUNVC5

Lamp: (2) FBO/835XP/ECO

Luminaire: GO2 2'X2' with 6 cell louver.

Ballast: Advance IOP-2P-32-LW-SC

Report is based on 2775 Lumens per lamp.

Efficiency: 79.5%
CIE Type-Direct-Indirect

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.1

1.6

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

21.000

21.000

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

4164.

6156.

6733.

55

3436.

4772.

4747.

65

2677.

2985.

1679.

75

2240.

2335.

2118.

85

1854.

1895.

1895.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

1 88 84 81 79 77 75 76 74 72

2 80 75 70 70 66 63 68 65 62

3 74 66 60 63 58 54 61 57 53

4 68 59 53 56 51 47 54 50 46

5 63 53 47 51 45 41 49 44 41

6 58 48 41 46 40 36 45 40 36

7 54 44 37 42 36 32 41 36 32

8 50 40 34 38 33 29 37 32 29

9 47 37 30 35 30 26 35 30 26

10 44 34 28 33 27 24 32 27 24

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

1391

25.1

31.6

0

0-

0

40

2317

41.8

52.5

0

0-

0

60

3867

69.7

87.7

0

0-

0

90

4411

79.5

100.0

90-180

000

0

0.0

00

0.0

0

0-180

4411

79.5

100.0

ZONAL LUMEN SUMMARY

0.0

45.0

90.0

FLUX

0

755

755

755

5

761

765

768

73

15

719

825

950

236

25

640

915

1094

408

35

536

857

979

503

45

403

663

657

466

55

271

383

283

307

65

157

153

106

149

75

80

86

75

85

85

22

24

21

26

90

3

3

2

Model No. GOS2G217UNVC2

LER = FP - 65.5      IW - 30.28      BF - 0.88

Comparative yearly lighting energy cost per

1000 lumens = $3.66

Report Number: G2008145

Catalog Number: GOS2G217UNVC2

Lamp: (2) F17/TL835/ALTO/PLUS

Luminaire: GO2 2'X2' with 6 cell louver.

Ballast: Advance IOP-2P-32-SC

Report is based on 1400 Lumens per lamp.

Efficiency: 80.5%
CIE Type-Direct-Indirect

Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.7

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

21.000

21.000

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

2002.

3294.

3265.

55

1660.

2346.

1734.

65

1305.

1272.

881.

75

1086.

1167.

1018.

85

887.

968.

847.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

1 89 85 82 80 78 76 77 75 74

2 82 76 71 71 68 64 69 66 63

3 75 67 61 64 59 55 62 58 54

4 69 60 52 57 52 48 55 51 47

5 64 54 47 52 46 42 50 45 41

6 59 49 42 47 41 37 46 40 37

7 55 45 38 43 37 33 42 36 33

8 51 41 34 39 33 29 38 33 29

9 48 37 31 36 30 27 35 30 26

10 45 34 28 33 28 24 33 27 24

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

717

25.6

31.8

0

0-

0

40

1220

43.6

54.2

0

0-

0

60

1993

71.2

88.4

0

0-

0

90

2253

80.5

100.0

90-180

000

0

0.0

00

0.0

0

0-180

2253

80.5

100.0

ZONAL LUMEN SUMMARY

Reviews: