iColor Flex LMX gen2 Product Guide
7
Photometrics
Photometric data is based on test results from an independent NIST traceable testing lab.
IES data is available at www.colorkinetics.com/support/ies.
Center Beam fc
Beam Width
4 ft
8 ft
12 ft
16 ft
20 ft
24 ft
1 fc
0 fc
0 fc
0 fc
0 fc
0 fc
10.5 ft
21.1 ft
31.6 ft
42.1 ft
52.7 ft
63.2 ft
10.2 ft
20.4 ft
30.6 ft
40.8 ft
51.1 ft
61.3 ft
Horiz. Spread: 103.8º
Vert. Spread: 105.6º
3.3 ft (1.0 m)
1 fc maximum distance
Illuminance at Distance
iColor Flex LMX gen2
Clear Flat Lens
Cd:
0
3
5
8
10
13
15
VA:
0º
10º
20º
30
40º
90º
80º
70º
60º
50º
- 0º H
- 90º H
0 25 45 70 90
0 11 11 11 11 11
5 11 11 11 11 11
15 11 11 11 11 11
25 10 10 10 10 10
35
9
9
9
9
9
45
7
7
7
7
7
55
5
5
5
5
5
65
3
3
3
3
3
75
1
1
1
1
1
85
0
0
0
0
0
90
0
0
0
0
0
Polar Candela Distribution
Effective Floor Cavity Reflectance: 20%
RCC %:
80
70
50
30
10
0
RW %:
RCR: 0
1
2
3
4
5
6
7
8
9
10
70 50 30 0
118 118 118 118
109 105 101 97
100 92 86 81
91 82 74 68
84 73 65 58
77 65 57 51
72 59 50 44
66 53 45 39
62 49 41 35
58 45 37 32
54 41 34 29
70 50 30 0
114 114 114 95
106 102 98 83
97 90 84 71
89 80 73 61
81 71 64 53
75 64 56 47
69 58 50 41
64 52 45 37
60 48 40 33
56 44 36 30
53 41 33 27
50 30 20
108 108 108
97 94 91
86 81 77
76 70 66
68 62 56
61 54 49
55 48 43
50 43 38
46 39 34
43 36 31
39 33 28
50 30 20
102 102 102
92 90 88
82 78 75
73 68 64
65 60 55
59 53 48
53 47 42
49 42 38
45 38 34
41 35 30
38 32 28
50 30 20
97 97 97
88 86 84
78 75 72
70 66 62
63 58 54
56 51 47
51 46 42
47 41 37
43 37 33
40 34 30
37 31 27
0
95
82
70
60
52
45
40
35
31
28
26
Coefficients Of Utilization - Zonal Cavity Method
ZONE
LUMENS
%FIXT
0-30
8.6
29.2
0-40
14.1
47.9
0-60
24.2
81.9
0-90
28.0
94.8
90-180
1.6
5.2
0-180
29.5
100.0
Zonal Lumen
iColor Flex LMX gen2
Translucent Dome Lens
Center Beam fc
Beam Width
4 ft
8 ft
12 ft
16 ft
20 ft
24 ft
0 fc
0 fc
0 fc
0 fc
0 fc
0 fc
62.9 ft
125.7 ft
188.6 ft
251.5 ft
314.3 ft
377.2 ft
80.6 ft
161.2 ft
241.9 ft
322.5 ft
403.1 ft
483.7 ft
Horiz. Spread: 168.7º
Vert. Spread: 165.5º
1.5 ft (1.4 m)
1 fc maximum distance
Illuminance at Distance
Cd:
0
1
2
3
3
4
5
VA:
0º
10º
20º
30
40º
90º
80º
70º
60º
50º
- 0º H
- 90º H
0 25 45 70 90
0 2
2
2
2
2
5 2
2
2
2
2
15 2
2
2
2
2
25 2
2
2
2
2
35 2
2
2
2
2
45 2
2
2
2
2
55 2
2
2
2
2
65 1
1
1
2
1
75 1
1
1
1
1
85 1
1
1
1
1
90 1
1
1
1
1
Polar Candela Distribution
Effective Floor Cavity Reflectance: 20%
RCC %:
80
70
50
30
10
0
RW %:
RCR: 0
1
2
3
4
5
6
7
8
9
10
70 50 30 0
114 114 114 114
100 93 88 82
89 79 71 64
80 68 59 51
73 60 50 43
67 53 43 36
61 47 38 31
57 42 33 27
53 39 30 24
49 35 27 21
46 32 24 19
70 50 30 0
109 109 109 78
95 89 84 58
84 75 68 46
76 65 56 37
69 57 48 31
63 50 41 27
58 45 36 23
54 41 32 20
50 37 29 18
46 34 26 16
43 31 23 14
50 30 20
99 99 99
80 76 73
68 62 57
59 52 46
52 44 38
46 38 32
41 33 28
37 30 24
34 27 21
31 24 19
28 22 17
50 30 20
90 90 90
73 69 66
61 57 52
53 47 42
47 40 35
41 35 30
37 31 26
34 27 23
31 25 20
28 22 18
26 20 16
50 30 20
82 82 82
66 63 61
55 51 48
48 43 39
42 37 33
37 32 28
34 28 24
31 25 21
28 23 19
26 20 17
24 19 15
0
78
57
44
36
29
25
21
19
16
15
13
Coefficients Of Utilization - Zonal Cavity Method
ZONE
LUMENS
%FIXT
0-30
1.8
14.1
0-40
3.1
23.9
0-60
6.0
46.8
0-90
10.0
78.2
90-180
2.8
21.8
0-180
12.8
100.0
Zonal Lumen
For lux multiply fc by 10.7
Lumens Efficacy
30
30
Lumens Efficacy
13
13