10

EN

5

4

6

1

2

3

Take out the humidification filter and the filter support from the water tank.

Remove the humidification filter from the filter support

Discard the used filter.

Remove the packaging material from the new humidification filter.

Assemble the new humidification filter around the filter support.

Put the filter and the filter support back into the water tank.

Put the upper unit back onto the water tank.

7 Troubleshooting

This chapter summarizes the most common problems you could encounter with 

the appliance. If you are unable to solve the problem with the information below, 

contact the Consumer Care Center in your country.

Problem

Possible solution

The humidifier does 

not work.

• 

Make sure that there is power supply to the humidifier.

• 

Make sure that the water tank is filled with water and 

the upper unit is placed properly onto the water tank.

There is no air 

humidification.

• 

Make sure that the water tank is filled with water and 

the upper unit is placed properly onto the water tank.

The water tank leaks.

• 

Make sure that the humidifier is not overfilled with 

water.

• 

Make sure that the humidifier is well assembled/

connected every time after you clean it or after you 

remove the upper unit and/or water tank for refilling.

• 

Make sure that the water tank is properly placed. If the 

problem persists, contact the Consumer Care Center in 

your country.

Summary of Contents for HU2510

Page 1: ...User manual HU2510 ...

Page 2: ...ication 6 4 Using the humidifier 6 Switching the humidifier on and off 6 Water level 7 Refilling water 7 5 Cleaning and maintenance 8 Cleaning the body of the humidifier 8 Cleaning the water tank 8 Cleaning the humidification filter 8 6 Replacing the humidification filter 9 7 Troubleshooting 10 8 Guarantee and service 12 Order parts or accessories 12 ...

Page 3: ...ironment Do not permit the area around the humidifier to become damp or wet If dampness occurs turn the output of the humidifier down If the humidifier output volume cannot be turned down use the humidifier intermittently Do not allow absorbent materials such as carpeting curtains drapes or tablecloths to become damp Never leave water in the reservoir when the appliance is not in use Empty and cle...

Page 4: ...g conditions Always place and use the appliance on a dry stable flat and horizontal surface Do not block the air inlet and outlet Do not place anything on top of the appliance and do not sit or stand on the appliance Only use the original Philips filter specially intended for this appliance Do not use any other filter Do not fill water from the air outlets on top of the appliance Only fill the wat...

Page 5: ...e filter will be deformed When the appliance is not used for a long time bacteria and mold may grow on the filter Clean the water tank and dry the humidification filter Check the filter before you start using the appliance again If the filter is very dirty with dark spots replace it Electromagnetic fields EMF This Philips appliance complies with all applicable standards and regulations regarding e...

Page 6: ...anced evaporation system with NanoCloud technology using a special humidification filter which adds H O molecules to the dry air and produces healthy humid air without formation of water mist Its humidification filter retains bacteria calcium and other particles from the water It delivers only pure humidified air in your home No more dry air in the winter season or from the air conditioning Read t...

Page 7: ...5 EN Product overview Humidification filter FY1190 Upper unit Filter support Water tank Gentle mode Power off button Turbo mode ...

Page 8: ...rt back into the water tank 5 Fill the water tank with cold tap water until water reaches the maximum water level indication 6 Place the upper unit back onto the water tank 4 Using the humidifier Switching the humidifier on and off 1 Put the plug of the humidifier into the power socket 2 Press or switch on the humidifier Gentle mode Turbo mode 3 Press the power button to switch off the humidifier ...

Page 9: ...water do not exceed the maximum water level or water might leak from the air inlets Do not shake the water tank when moving it or water might leak from the air inlets Do not fill water through the air outlets on top of the humidifier 1 Switch off the humidifier and unplug it 2 3 4 2 Remove the upper unit by holding it at both sides 3 Fill the water tank with cold tap water until water reaches the ...

Page 10: ...leaning the water tank Clean the water tank every weeks to keep it hygienic 1 Take out the humidification filter and the filter support 2 Add some mild washing up liquid mixed with water in the water tank 3 Clean the inside of the water tank with a soft clean cloth 4 Empty the water tank into a sink 5 Put the humidification filter and the filter support back into the water tank Cleaning the humidi...

Page 11: ...act humidification performance Do not dry the filter under direct sunlight unless it is assembled back onto the filter support 6 Replacing the humidification filter Note Use only Philips original humidification filter FY1190 Always unplug the humidifier before you replace the humidification filter Register your product at www philips com for further information on how to replace your filter Do not...

Page 12: ...information below contact the Consumer Care Center in your country Problem Possible solution The humidifier does not work Make sure that there is power supply to the humidifier Make sure that the water tank is filled with water and the upper unit is placed properly onto the water tank There is no air humidification Make sure that the water tank is filled with water and the upper unit is placed pro...

Page 13: ...place the humidification filter every 6 months There is unpleasant smell coming out from the humidifier Make sure that the water tank is filled with water Clean the humidification filter see the chapter Clean the humidification filter No air comes out of the air outlet Put the plug of the humidifier into the power socket and switch on the humidifier I do not see visible mist coming out of the humi...

Page 14: ...ldwide guarantee leaflet If there is no Consumer Care Center in your country go to your local Philips dealer Order parts or accessories If you have to replace a part or want to purchase an additional part go to your Philips dealer or visit www philips com support If you have problems obtaining the parts please contact the Philips Consumer Care Center in your country you can find its phone number i...

Page 15: ... 2022 Philips Domestic Appliances Holding B V All rights reserved HU2510_user manual_v1 0 15 06 2022 ...

Reviews: