1.0 TECHNICAL SPECIFICATION and SERVICE HINTS
Recovery procedure for flash
corrupt problem
If the device cannot be powered on but it can be
detected by DFU program (device firmware upgrade
application), it can be recovered by following the
procedure below.
Note: Close all applications e.g. Philips Device
Manager before launch the DFU program. Run this
program by Window XP only.
For HDD084 only (MSC mode device)
1. Connect the DFU USB cable to the device first
and then connect to your PC.
2. Launch the DFU program by unzip the
Symphony.rar
file and then double click the
DFUAPP.exe
file from
Symphony
folder.
3.
Observe the dialogue box to ensure
“DEVICE
IS IN DFU MODE”
.
4. Select
Download
and then click
Browse
to get
the
FWImage.ebn
file from your PC.
5. Click
Start Download
to download the firmware
to the device.
6. The program will stop once the successful
message is display.
7. Disconnect DFU USB cable from the device.
8. Connect the device to the PC by normal USB
cable and launch the Philips Device Manager to
repair the device. (Download the latest version
of the Device Manager application from Philips
support website http://www.philips.com/support)