1.0 TECHNICAL SPECIFICATION and SERVICE HINTS
8. Once the GoGear micro jukebox is disconnected
from the computer, the display will show “Firmware
Upgrading” for a couple of seconds and then start
up as usual. If the message does not disappear
after 2 minutes, do a soft reset by pressing and
holding the
key and the key for a
couple of seconds.
For HDD085/HDD082
1. Download the latest version of the Device
Manager application from
http://www.philips.com/support. You may need to
enter your language preference and the model
number e.g. hdd085, to access the Device
Manager application upgrade file.
2. Double click the downloaded execution file to start
the installation of the Device Manager.
3. Connect the GoGear to the power supply with the
AC/DC adapter and to the computer with the
provided USB cable. Make sure that Windows
Media Player along with any other applications are
closed.
4. Launch the Philips Device Manager by double
clicking the Device Manager icon at the task bar
on your computer.
5. The Philips Device Manager will detect the
connection of your GoGear and the application will
automatically check on the server to see if an
update is available and prompt user to download
the updated firmware. Click YES to start the
downloading.
6. A status bar will show the downloading progress of
the firmware. Once the downloading is complete
the application will prompt you to install the update
onto your GoGear. Click YES to confirm
7. The application will show the status of updating
and at the end you need to click OK to complete
the update. (Please do not disconnect the jukebox
during the upgrading process as this interruption
may damage the firmware!)
8. Once the success message is displayed. Close
Device Manager and all opened application and
unplug your GoGear.
Service Hints
Rebuild database & firmware after
replacement of hard disk drive
IMPORTANT: All devices having the hard disk
replaced must have the firmware image & database
rebuilt before returning to customers.
After the replacement of hard disk the database and
firmware image must be rebuilt in the device with
device manager by following the procedure below.
For HDD084
1. Connect the GoGear to the power supply with the