12
Alarm Out:
The
Alarm Output
is activated when a teletext alarm is read, or while the
Alarm Input is active. The Alarm output is only active for the duration of the alarm
event.
Record Start In:
When activated, this connection places the unit in record mode.
Compatible with the
Disk End Out
signal from a second unit.
Alarm Record Reset:
This feature is for future development and has not yet been
implemented.
VEXT Pulse Out:
The
Video External Pulse Connection
(VEXT) simplifies
multiplexer operation by automatically synchronizing the multiplexer with the DVR1.
The DVR1 sends a VEXT pulse to the multiplexer, indicating that it is ready to
record the next image. The multiplexer responds by sending the next image to the
Video Input
on the DVR1.
The VEXT connection is especially beneficial for units configured with dual record
speeds (Normal and Alarm).
NOTE
:
Use of the VEXT connection is highly recommended when connecting
the unit to a multiplexer.
Error Out:
The
Error Out
signal is activated when the unit experiences any
operational or internal error.
Videoloss Out:
The
Videoloss Out
signal is activated when the unit experiences
loss of video on the selected video input (Composite or S-video).
In the event of loss of video,
VIDEOLOSS
will be indicated near the upper
left-hand corner of the primary monitor.
Disk End Out:
The
Disk End Out
is activated when there are 5 minutes of
recording space left on the hard disk.
Output:
Active Low
High:
5 V
Low:
Ground (0.8 V Max)
Current Out:
50 mA Max
Short Circuit Protected.
Output:
Open Collector
High:
Transistor Off
Low:
Transistor On
Active When On.
Current Out:
10 mA Max
Minimum Duration: 0.5 Seconds
Input:
Active Low
High:
12 V
Low:
Ground
Current Out:
50 mA Max
Short Circuit Protected.
Low for duration of alarm
Input:
Active Low TTL with pull-ups
or Normally Open Relay.
High:
5 V (12 V tolerant)
Low:
Ground
Minimum Duration: 0.5 Seconds