1-4-11
E9480FIS
Perform an IIC write action on the digital board.
120900
Writing the data over IIC succeeded.
120901
No input specified.
120902
Invalid Bus ID number.
120903
No IIC address.
120904
Invalid IIC address.
120905
No number of bytes input.
120906
Invalid number of bytes.
120907
No Data.
120908
Number of bytes must be > 0 and < 18.
120909
Invalid Data.
120910
Not enough data bytes.
120911
IIC Write failed.
120912
IIC init failed.
Perform an IIC read action on the digital board.
121000
Reading the data over IIC succeeded.
121001
No input specified.
121002
Invalid Bus ID number.
121003
No IIC address.
121004
Invalid IIC address.
121005
No number of bytes input.
121006
Invalid number of bytes.
121007
Number of bytes must be > 0 and < 101.
121008
IIC Read failed.
121009
IIC init failed.
Perform an UART write action on the digital board on a
specified UART.
121100
Writing the bytes to the UART succeeded.
121101
The user provided wrong input.
121102
Writing to the UART failed.
Perform an UART read action on the digital board on a
specified UART
121200
Reading the data from the UART succeeded.
121201
The user provided wrong input.
121202
Reading the data from the UART failed.
The video signal, which is determined by the user
input, is routed from the input to the output. Input is set
with the routing nucleus 1112. All outputs are enabled.
Audio loopthrough is also enabled by this nucleus.
121300
Video LoopthroughStart succeeded.
121302
Invalid input parameters.
121303
Failed to initialise DENC.
121304
Failed to initialise VIP.
121305
DSW not ready for this setting yet.
Stop routing the audio/video input to all the outputs..
121400
VideoLoopthroughStop succeeded.
Set the slash version of the system.
121700
Setting the slash version succeeded.
121701
Invalid slash version, default version is set.
121702
Setting the slash version failed.
121703
The user provided wrong input.
121705
No DS errCode known for analogue board error:
121706
There was no response from the analogue board.
Get the slash version of the system.
121800
Getting the slash version succeeded.
121801
Getting the slash version failed.
121802
The IIC write failed.
121803
The IIC read failed.
121804
There was no response from the analogue board.
121805
No DS errCode known for analogue board error:
(Re-) Virginize the recorder. User data in the NVRAM
of the analogue board is cleared.
121900
Virginization succeeded.
121901
Virginization on the Analogue Board failed.
121903
No DS errCode known for analogue board error:
121904
There was no response from the analogue board.
Turn on the virgin mode functionality (e.g. the auto
channel search upon startup).
122000
Turning on the virgin mode succeeded.
122001
urning on VirginMode on the Analogue Board failed.
122003
No DS errCode known for analogue board error:
122004
There was no response from the analogue board.
Description
Error No.
Error Description
Summary of Contents for DVDR600VR/37
Page 26: ...1 6 1 E9480IB OPERATING CONTROLS AND FUNCTIONS DVDR600VR 37 ...
Page 27: ...1 6 2 E9480IB ...
Page 28: ...1 6 3 E9480IB ...
Page 29: ...1 6 4 E9480IB MRV700VR 17 ...
Page 30: ...1 6 5 E9480IB ...
Page 31: ...1 6 6 E9480IB ...
Page 32: ...1 7 1 E9480IBR REMOTE CONTROL OPERATION DVDR600VR 37 ...
Page 33: ...1 7 2 E9480IBR ...
Page 34: ...1 7 3 E9480IBR MRV700VR 17 ...
Page 35: ...1 7 4 E9480IBR ...
Page 41: ...1 8 6 E9480DC Fig D9 22 Deck Pedestal 23 Front Bracket R iLink Cable S 25 S 25 S 26 S 27 A ...
Page 91: ...Digital Board Unit Top View DVD Section 1 12 65 1 12 66 ...
Page 92: ...Digital Board Unit Bottom View DVD Section 1 12 67 1 12 68 ...
Page 93: ...Digital Board Unit Test Point View DVD Section 1 12 69 1 12 70 ...
Page 155: ...Directions For Use EN 4 VAD8041 3 3 Directions For Use Not applicable ...
Page 181: ...EN 30 VAD 8041 7 Electrical Diagrams and Print Layouts ...
Page 200: ...Spareparts List EN 49 VAD8041 10 DVD M TR 22003_001 300604 ...