4-3 Adjustment Method
1. TP403, B+ voltage adjustment:
A. Chroma-2135 Signal generator or PC equivalent set timing 140, pattern 101.
B. Connect a DC Volt meter between TP403 and ground, then adjust VR902 to be 125 VDC for CPT CRT and
125 VDC for LPD CRT,set G2 for 560VDC.
C. Set the contrast and brightness max,and then adjust focus and make the screen clear.