Philio PSR07 Manual Download Page 3

 

Configuration

 

 

NO.  Name 

Size 

(Byte) 

Def. 

Valid  

Values 

Description

 

 
 

 
 

Basic Set 

OFF level 

 
 

 
 

0x00 

 
 

0x00~0x63 

Control the value represented 

by the left-side in area D. 

E.g. Setting this configuration 

to 0x0F means range of 

Command Basic Set value 

start from 0x0F

 

 

 

 

 

Basic Set 

ON level 

 

 

 

 

0x63 

 

 

0x00~0x63 

Control the value represented 

by the right-side in area D. 

E.g. Setting this configuration 

to 0x1E means range of 

Command Basic Set value 

start from 0x1E

 

 
 

10 

Auto 

Report 

Battery 

Time 

 
 

 
 

12 

 
 

1~127 

The interval time for auto 
reporting the Battery level. 0 

means turn off auto report 

battery. 
The default value is 12.

 

 

 

25 

 

Dimmer 

Set 

Method 

 

 

 

 

0x00 

 

 

0x00,0x01 

Dimmer setting method. 

0 : Auto send Command 

Basic Set after rotating. 
1 : Send Command Basic Set 

by touching key after rotating 

 

 

Installation

 

 

1. Fix the bracket on the wall. 

2. There's a magnet on the backside of this device. It can stick to the 
bracket.

 

Notice: Do not install the bracket on unstable wall, this may 
cause miscarriage to control lights.

 

 

 Firmware update over the air (OTA)

 

 

This device supports the Z-Wave firmware update via OTA. Let the 

controller into the firmware update mode, and rotate to area A then 
touch  the  button  once  to  start  update.  After  finish  the  firmware 

download,  the  red  LED  will  start  to  flash  every  0.5  second.  Please 

don't remove the battery before the LED stop flashing.

 

Notice: recommend using OTA when the device is charging. 

 

 

 

Supported Z-Wave Command Classes

 

 

* COMMAND_CLASS_ZWAVEPLUS_INFO_V2 

* COMMAND_CLASS_BATTERY 

* COMMAND_CLASS_CENTRAL_SCENE_V1 

* COMMAND_CLASS_VERSION_V2 

* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 

* COMMAND_CLASS_DEVICE_RESET_LOCALLY 

* COMMAND_CLASS_ASSOCIATION_V2 

* COMMAND_CLASS_WAKE_UP_V2 

* COMMAND_CLASS_ASSOCIATION_GRP_INFO 

* COMMAND_CLASS_POWERLEVEL 

* COMMAND_CLASS_MULTI_CMD 

* COMMAND_CLASS_SECURITY 

* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 

* COMMAND_CLASS_CONFIGURATION 

 

Security Network

 

The device support the security function. When the device included 

with a security controller, the device will auto switch to the security 

mode.  In  the  security  mode,  the  follow  commands  need  using 

Security CC wrapped to communicate, otherwise it will not response. 

 

COMMAND_CLASS_BATTERY 

COMMAND_CLASS_ASSOCIATION_V2 

COMMAND_CLASS_CONFIGURATION 

COMMAND_CLASS_WAKE_UP_V2 

COMMAND_CLASS_CENTRAL_SCENE

 

 

Summary of Contents for PSR07

Page 1: ...ld be included in 5 seconds Red LED will light ON one second Rotating to area A shown in Fig 1 and touch 3 times can abort NWI mode There is a touch button on the front side The button carries out manual inclusion exclusion and reset to default 1 Include Pointing the arrowhead to area A first shown in Fig 1 Pressing the button three times within 1 5 seconds The red LED will light up for 1 second i...

Page 2: ...ate PSR07 to area A then touch the button Group 1 is for receiving the report message like the battery level Group 2 is for light control the device will send Basic Set command to this group Timing Report The device supports the timing unsolicited report of the status Battery level report Every 6 hours report once in default It could be changed by setting the configuration NO 10 Low battery report...

Page 3: ...device supports the Z Wave firmware update via OTA Let the controller into the firmware update mode and rotate to area A then touch the button once to start update After finish the firmware download the red LED will start to flash every 0 5 second Please don t remove the battery before the LED stop flashing Notice recommend using OTA when the device is charging Supported Z Wave Command Classes COM...

Page 4: ... to turn the lamp on then adjust the percentage The device can not join to Z Wave network 1 The device may in a Z Wave network 2 The arrowhead points to wrong area 1 Exclude the device then include again 2 Pointing the arrowhead to area A then include again Button no response 1 The button will no response when LED is flashing Wait for the LED go out and try again Specification Operating Voltage 3 ...

Page 5: ...cordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the followi...