background image

Overview

                                                                

Specification

Rated Voltage

DC 5V/1A from USB

Range

Minimum 40M in door and 100M in outdoor line of 
sight

Operating Temperature

-10°C ~ 40°C (85% humidity)

Storage Temperature

-20 C ~ 60°C

Location

Indoor use only

Dimension

65(L) x 44.1 (W) x 56.3 (H) mm

CO2

65535ppm

Frequency Range

868.40MHz; 869.85MHz (EU)

908.40MHz; 916.00MHz (USA/Canada)

916MHz (Israel)

922.5MHz, 923.9MHz, 926.3MHz (JP)

RF Maximum Power (peak) +5dBm (peak)

RF Maximum Power 
(Average)

-10dBm (Average)

RF Modulation Type

FSK (Frequency-Shift Keying)

FCC ID

RHHPAT12

                                                        

Disposal

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible harm to
the environment or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse of material 
resources. To return your used device, please use the return and 
collection systems or contact the retailer where the product was 
purchased. They can take this product for environmental safe recycling.

Philio Technology Corporation
8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan
www.philio-tech.com

FCC Interference Statement

This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to

5

Summary of Contents for PAT12-A

Page 1: ...nabled Z Wave Plus product that is able to use encrypted Z Wave Plus messages to communicate to other security enabled Z Wave Plus products This device must be used in conjunction with a Security Enable Z Wave Controller in order to fully utilize all implemented functions The device adopts the Z WaveTM 500 series chip when your Z WaveTM network system is made by Z WaveTM 500 series devices This ne...

Page 2: ...provided by the controller manufacturer 2 Press the include button of the PAT12 three times within 3 seconds to enter exclusion mode 3 Node ID has been excluded If the remove successful the LED light will flash for 120 seconds Reset 1 Press the include button of Use this procedure only the PAT12 three times within 3 seconds to enter inclusion mode 2 Within 1 second again press the include button o...

Page 3: ...ess ful the LED light will flash slowly Z Wave Message Report CO2 Report When the CO2 Concentration differential over 1 percent in default or across the baseline level the device will unsolicited to send the Sensor Multilevel Report to the nodes in the group 1 Multilevel Sensor Report Sensor Type CO2 0x11 Note 1 This function default is enabled to disable this function by setting the configuration...

Page 4: ... Specific 2 Highest granted Security Class Device Reset Locally 1 Highest granted Security Class Powerlevel 1 Highest granted Security Class Security 2 1 None Configuration 1 Highest granted Security Class Notification 8 Highest granted Security Class Security 0 1 None Sensor Multilevel 11 Highest granted Security Class Supervision 1 None Firmware Update Meta Data 4 Highest granted Security Class ...

Page 5: ...his product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this p...

Page 6: ...r help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s ...

Reviews: