Before starting the update, please remove the front case of the device otherwise the
hardware check will fail.
Let the controller into firmware update mode, and press the front tamper key once to
start the update.
After firmware download is complete, the LED light will flash intermittently.
Z-Wave Supported Command Classes
The device supports the security function.when the device include with
a security controller, the device will auto switch to the security mode.In
the security mode, the follow commands need using Security CC
wrapped to communicate.
Command Class
Version Required Security Class
Z-Wave Plus Info
2
None
Association
2
Highest granted Security Class
Association Grp Info
1
Highest granted Security Class
Transport Service
2
None
Version
3
Highest granted Security Class
Manufacturer Specific
2
Highest granted Security Class
Device Reset Locally
1
Highest granted Security Class
Powerlevel
1
Highest granted Security Class
Security 2
1
None
Configuration
1
Highest granted Security Class
Notification
8
Highest granted Security Class
Security 0
1
None
Sensor Multilevel
11
Highest granted Security Class
Supervision
1
None
Firmware Update Meta Data
4
Highest granted Security Class
Z-Wave Configuration Settings
NO. Name
Size
(Byte)
Valid
Def. Description
1
Auto report CO2 Concentra-
tion time
2
1~32767
60
Units of 1 minute.
2
CO2 Concentration differen-
tial report
1
0~100
10
Units of 1 %.
0 means turn off the report
3
Baseline level 1
1
0~50
0
Units of 100 ppm.
0 means turn off the report
4
Baseline level 2
1
0~50
0
Units of 100 ppm.
0 means turn off the report
5
Baseline level 3
1
0~50
0
Units of 100 ppm.
0 means turn off the report
6
Baseline level 4
1
0~50
0
Units of 100 ppm.
0 means turn off the report
7
Baseline level 5
1
0~50
0
Units of 100 ppm.
0 means turn off the report