Sensor Binary Report (V2)
Sensor Type: Water (0x06)

Sensor Value: 0xFF

And after the flood trigger clear, the device will unsolicited to send the

report to the nodes in the group 1.

Notification Report (V4)
Notification Type: Water Alarm (0x05)

Event: 0x00
Sensor Binary Report (V2)
Sensor Type: Water (0x06)

Sensor Value: 0x00

* Tamper Report: (PAT02-A, PAT02-B, PAT02-C)

The tamper key pressed over 5 seconds. The device will into the alarm

state.   In   that   state,   if   the   tamper   key   be   released,   the   device   will

unsolicited to send the report to the nodes in the group 1.

Notification Report (V4)
Notification Type: Home Security (0x07)

Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08)

Sensor Value: 0xFF

* Temperature Report: (PAT02-A, PAT02-B)

When   the  flood   triggered  or  the   temperature   differential   over   1

Fahrenheit (in default), the device will unsolicited to send the “Sensor

Multilevel Report” to the nodes in the group 1.

Sensor Type: Temperature (0x01)

Note:   To   disable  send   temperature   report   after   the   flood   triggered,

please setting the configuration N0.5 bit5 to 1.

*** Temperature differential report ***

This function default is enabled, to disable this function by setting the

configuration NO.21 to 0.

In the default, when the temperature is changed to plus or minus one

degree   Fahrenheit   (0.56  degree   Celsius),   the   device   will   report

temperature information to the nodes in the group 1. 

The device will measure the temperature in every  10 seconds. And if

the temperature is over 140 degree Fahrenheit (60 degree Celsius), the

device will always report in each measurement. 

* Humidity Report: (PAT02-A, PAT02-B)

When the flood triggered or the humidity differential over 5 percent (in

default),   the   device   will   unsolicited   to   send   the   “Sensor   Multilevel

Report” to the nodes in the group 1.

Sensor Type: Humidity (0x05)

Note: To disable send humidity report after the flood triggered, please

setting the configuration N0.6 bit6 to 1.

*** Humidity differential report ***

This function default is enabled, to disable this function by setting the

configuration NO.23 to zero.

Enable this functionality, the device will measure the humidity in every

10 seconds. And if the humidity is changed to plus or minus the value

(setting by the configuration NO.23), the device will report  humidity

information to the nodes in the group 1. 

* Timing Report:

Beside   the   event   triggered   could   report   message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

3

Summary of Contents for PAT02-A-NS

Page 1: ...ice adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Function Compare A B C Flood Temperature Humidity PAT02 A NS V ...

Page 2: ...e group 2 is for the light control the device will send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeo...

Page 3: ...to disable this function by setting the configuration NO 21 to 0 In the default when the temperature is changed to plus or minus one degree Fahrenheit 0 56 degree Celsius the device will report temperature information to the nodes in the group 1 The device will measure the temperature in every 10 seconds And if the temperature is over 140 degree Fahrenheit 60 degree Celsius the device will always ...

Page 4: ...e flash about 5 seconds Please change another new battery NWI When the device power on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller The use can presses the tamper key 3 times to abort the NWI mode PS If the device alrea...

Page 5: ... The way to open the front cover please press the top position to release the cover Replace the new battery and install the cover back 1 Put the front cover bottom and press down 2 Push the front cover top Installation 1 To mount the device on the wall you can choose using the tape or the screw 2 Using the screw to fix the flood detector 5 1 1 2 ...

Page 6: ... 0x00 send the BASIC CC to the group 2 2 Basic Set ON Level 0xFF All Setting the BASIC command value When the flood trigger on 0xFF send the BASIC CC to the group 2 5 Operation Mode All 0 33 32 Operation mode Using bit to control 0 Bit0 Disable the Flood function 0 Bit1 Reserve 0 Bit2 Reserve 0 Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius 0 Bit4 Reserve 0 Bit5 Disable the temperature ...

Page 7: ...emperatur e Time 12 0 127 The interval time for auto report the temperature 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 14 Auto Report Humidity Time 12 0 127 The interval time for auto report the humidity 0 means turn off auto report The default value is 12 The tick time can setting by the configuration No 20 15 Auto Report Flood Time 1...

Page 8: ..._SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SENSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 Specifications Power by CR123A lithium battery Signal Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 00 MHz US 92...

Page 9: ... to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modi...

Reviews: