5
3-3 Manual On/Off Mode
The On/Off function of S1
、
S2 and learn switch can be disabled or enabled by this
parameter, default value is Enable. But the learning operation won’t be affected.
3-4 LED indication Mode
3-4-1 Show switch state
:
LED on for switch on and off for switch off. The default
value is Show switch state.
3-4-2 Show night mode
:
LED off for switch on and on for switch off.
3-4-3 One Flash mode
:
When the state of switch changes, LED will be on only one
second, then LED keeps off.
3-5 Auto Off timer
When auto off timer is equal to 0, the auto off function will be disabled. Whenever
the switch is set to on, the auto off timer begin to count down. After the timer
counts to zero, PAN05 will switch off automatically. The default value is disable
auto off function.
3-6 RF Off command mode
Whenever a RF Off command is received, BASIC_SET
、
BINARY_SWITCH_SET
、
SWITCH_ALL_OFF, it could be interpreted as Switch Off
、
Switch On
、
Switch
Toggle, or it would be ignored. The default value is Switch Off.
4. Protection Command Classes
PAN05 supports Protection Command Class version 2, it can protect the switch
against unintentionally control by e.g. a child. And it can also protect the switch
from being turned off by setting it in “No RF Control” state.
After being set to “Protection by sequence” state, any intentional pressing of
On/Off button or S1/S2 should be hold longer than 1 second, or the switch state
will not change.
However, the operation of learn function does not change, because learning will
not be protected.
5. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_ZWAVEPLUS_INFO_V2
* COMMAND_CLASS_VERSION_V2
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_SECURITY
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_SWITCH_ALL
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_ALARM
* COMMAND_CLASS_PROTECTION_V2
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Troubleshooting
Symptom
Cause of Failure
Recommendation
The Switch not working and
LED off
1. The Switch is not
connect to the Main
power
2. The Switch break
down
1. Check power connections
2. Don’t open up the Switch and send
it for repair.
The Switch LED
illuminating, but cannot
control the ON/OFF
Switch of the load attached
Check if the load connect
into the Switch has its
own ON/OFF switch
Set the ON/OFF switch of the load
attached to ON
The Switch LED
illuminating, but the
detector cannot control
the Switch
1. Not carry out
association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
LED keep flashing
continuously, but cannot
control
Overload occurs
Remove the load attached or check
max. load cannot exceed
85 °C (230Vac/120Vac)