2-1 Auto report to Grouping 1 (Maximum Node 1) 

 
2-1-1 On/Off Event Report   

      When  “on”  or  “off”  state  has  been  changed  (ex.  Press  S1  S2  or  include  on/off 

button), it will send Binary Switch Report to the nodes of Group1.   

       

Binary Switch Report 
 

ON:[Command Class Switch Binary, Switch Binary Report, Value 

=(255)0xFF] 

OFF:[Command Class Switch Binary, Switch Binary Report, Value 

=0(0x00)]

 

 

2-1-2 Overload alarm report command 

      When PAN05 detect the overload, it will send Alarm Report to the node of 

Group1. 

 
The content of Alarm Report 
 

Alarm report command:[Command Class Alarm, Alarm Report, Alarm Type 

= 0x08, Alarm Level = 0xFF]

 

 

2.  Z-Wave’s Configuration 
 

Configuration 
Parameter 

Function 

Size 
(Byte) 

Value 

Unit 

Default  Description

 

Edge or 
Pulse 
mode or 
Edge-Tog 
gle mode 

1-3 

 

1

 

1

Edge mode 

2

Pulse mode 

3

Edge-Toggle 

mode

 

Restore 
switch 
state 
mode 

0-2 

 

1

 

0 : Switch Off 
1 : Last Switch 

State 

2 : Switch On

 

Manual 
On/Off 
mode 

0-1 

 

1

 

0

Disable 

manual On/Off 

1

Enable 

manual On/Off

 

LED 
indication 

1-3 

 

1

 

1

Show switch 

state 

mode 

2

Show night 

mode 

3 : One flash 

mode 

Auto off 
timer 

0-0x7F
FF

 

Second

  0

 

0

Disable auto 

off function 

1-0x7FFF

1 ~ 

32767seconds

 

RF Off 
command 
mode 

0-3 

 

0

 

0

Switch off 

1

Ignore 

2

Switch toggle 

3

Switch on

 

 

3-1 Edge / Pulse / Edge-Toggle mode 

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle 

mode, default value is Edge mode. 

3-1-1 Edge mode: this mode is suitable for the bi stable wall switch that has indicator 

point on the switch, and the same position correspond to same state of relay1. 

if the PAN05 relay change the state because of receiving Z-Wave RF 

command, it may need two times of change (switch on to off or switch off to on) 

to let relay back to the correspond state. Manual switch S2 is disabled in 

this mode. 

3-1-2 Pulse mode: this mode is suitable for the toggle type wall switch to swap the 

state of Relay1. 

3-1-3 Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every 

time when change the state of the wall switch will also swap the state of 

Relay1.       

3-2 Restore Switch State Mode 

Whenever the AC power reconnected to PAN05, it will set the switch to Off

On or 

Last switch state, default value is Last switch state.   

Summary of Contents for PAN05-1A

Page 1: ...nect the COM terminal directly to AC Line terminal the new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent fluorescent and LED light This module can also connect to alternative power supply like DC 12V to switch on off 12V MR 16 light as follow picture Adding to Z WaveTM Network In the f...

Page 2: ...n 1 The PAN05 is an always listening Z Wave device so associations may be added or removed by a controller at any time Or If your controller requires to have the PAN05 send a node information frame or NIF for associations then pressing the On Off button three times within 2 seconds will cause the PAN05 to send its NIF 2 There are only one group for the switch Including a node ID allocated by Z Wav...

Page 3: ...that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Basic Get Command Command Class Basic Basic Get Basic Report Command Report OFF Command Class Basic Basic Report Value 0 0x00 Report ON Command Class Basic Basic Report Value 255 0xFF Binary Switch Get Command Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Command Class Switch Binary Switch Bi...

Page 4: ...witch state mode 2 Show night mode 3 One flash mode 5 Auto off timer 1 0 0x7F FF Second 0 0 Disable auto off function 1 0x7FFF 1 32767seconds 6 RF Off command mode 1 0 3 0 0 Switch off 1 Ignore 2 Switch toggle 3 Switch on 3 1 Edge Pulse Edge Toggle mode Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge Toggle mode default value is Edge mode 3 1 1 Edge mode this mode is suitable fo...

Page 5: ...ate any intentional pressing of On Off button or S1 S2 should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Command Classes The Switch supports Command Classes including COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_SECU...

Page 6: ...ass B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that...

Reviews: