Choosing a Suitable Location 
 

1.  Do not locate the Switch facing direct sunlight, humid or dusty place. 

2.  The suitable ambient temperature for the Switch is 0°C~40°C. 

3.  Do not locate the Switch where exists combustible substances or any source of 

heat, e.g. fires, radiators, boiler etc. 

4. 

After putting it into use, the body of Switch will become a little bit hot of which 

phenomenon is normal.

 

 
Installation

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.  Put  the  in  wall  switch  into  a  wall  box  and  connect  the  AC  power  wire  L,  N  to 

PAN05 connector L, N. 

2.  Connect the wall switch to the PAN05 as Fig1. 
3.  There are 3 mode PAN05 can be configured to match different kind of wall switch, 

please  refer  to  3-1  Edge  /  Pulse  /  Edge-Toggle  mode  which  described  in  next 
section of this user manual.   

4.  If Edge-Toggle mode has been set, and the S1 S2 is connect to normal bi-stable 

switch,  every  time  when  change  the  state  of  the  wall  switch  will  also  swap  the 
state of Relay1. 

 

Programming 
 

1.    Basic Command Class / Binary Switch Command Class 

The  Switch  will  respond  to  BASIC  and  BINARY  commands  that  are  part  of  the 
Z-Wave system. 

 

1-1 BASIC_GET / BINARY_SWITCH_GET 
 

Basic Get Command: [Command Class Basic, Basic Get]

 

Basic Report Command: 
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] 
Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]

 

 

Binary  Switch  Get  Command:[Command  Class  Switch  Binary,  Switch 
Binary Get]

 

Binary Switch Report Command: 
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value 
=0(0x00)]
 
Report ON:[Command Class Switch Binary, Switch Binary Report, Value = 
255(0xFF)]

 

 

1-2 BASIC_SET / SWITCH_BINARY_SET 

 

 

 

 

 

 

   

[Command  Class  Basic,  Basic  Set,  Value  =  1~99,  255(0xFF)]:  the  load 
attached to the Switch turns on.

 

[Command  Class  Basic,  Basic  Set,  Value  =  0(0x00)]:  the  load  attached  to 
the Switch turns off.

 

[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  1~99, 
255(0xFF)]
: the load attached to the Switch turns on.

 

[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  0(0x00)]:  the 
load attached to the Switch turns off.

 

 

1.  Z-Wave’s Groups (Association Command Class Version 2) 
 
The Switch can be set to send reports to associated Z-Wave devices. It supports only 
one association group and the group has one node support. Group1 support 
SWITCH_BINARY_REPORT. 
 
For group 1, the Switch will report ON/OFF status of Relay to controller. 
 

Summary of Contents for PAN05-1A

Page 1: ...nect the COM terminal directly to AC Line terminal the new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent fluorescent and LED light This module can also connect to alternative power supply like DC 12V to switch on off 12V MR 16 light as follow picture Adding to Z WaveTM Network In the f...

Page 2: ...n 1 The PAN05 is an always listening Z Wave device so associations may be added or removed by a controller at any time Or If your controller requires to have the PAN05 send a node information frame or NIF for associations then pressing the On Off button three times within 2 seconds will cause the PAN05 to send its NIF 2 There are only one group for the switch Including a node ID allocated by Z Wav...

Page 3: ...that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Basic Get Command Command Class Basic Basic Get Basic Report Command Report OFF Command Class Basic Basic Report Value 0 0x00 Report ON Command Class Basic Basic Report Value 255 0xFF Binary Switch Get Command Command Class Switch Binary Switch Binary Get Binary Switch Report Command Report OFF Command Class Switch Binary Switch Bi...

Page 4: ...witch state mode 2 Show night mode 3 One flash mode 5 Auto off timer 1 0 0x7F FF Second 0 0 Disable auto off function 1 0x7FFF 1 32767seconds 6 RF Off command mode 1 0 3 0 0 Switch off 1 Ignore 2 Switch toggle 3 Switch on 3 1 Edge Pulse Edge Toggle mode Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge Toggle mode default value is Edge mode 3 1 1 Edge mode this mode is suitable fo...

Page 5: ...ate any intentional pressing of On Off button or S1 S2 should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Command Classes The Switch supports Command Classes including COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_SECU...

Page 6: ...ass B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that...