OVP-17P

Voltage Relay 

Summary of Contents for OVP-17P

Page 1: ...USER S MANUAL www sven fi OVP 17P Voltage Relay ...

Page 2: ...ON Despite the exerted efforts to make this Manual more exact some discre pancies may occur The information in this Manual is given on as is terms The author and the publisher do not bear any liability to a person or an or ganization for loss or damage which has arisen from the information con tained in this Manual CONTENTS 1 PRECAUTIONS 2 PACKAGE CONTENTS 3 APPLICATION 4 FEATURES 5 TECHNICAL DESCR...

Page 3: ... organic compounds alcohol petrol solvents etc to clean the device It is prohibited to open and repair the device on your own It is prohibited to open and repair any protected equipment if it is con nected to the device socket It is prohibited to use the device with mechanical damages of its case It is prohibited to use the device in high humidity conditions Avoid ingress of water into the device ...

Page 4: ...k delay time and protection status indication Protective shutters in the output socket Protective grounding connection 5 TECHNICAL DESCRIPTION OVP 17P voltage relay presents a device with an electronic circuit with microprocessor control assembled in a case with a wall plug and socket OVP 17P voltage relay provides the power supply disconnection of appliances connected to it if the power supply vo...

Page 5: ...ters being set and the voltage relay status indication b SET button to enter the programming mode and select programmable parameters c Λ button to increase the value of a parameter being set d V button to decrease the value of a parameter being set e RES reset button f Protective shutters g Grounding contacts h Wall plug to connect the voltage relay to 220 230 V 50 Hz power supply network socket F...

Page 6: ...ssary to set actuation values namely high voltage switching off threshold UH low voltage switching off threshold UL and turn on delay time after voltage normalization of the power supply network td see p 7 It is recom mended to set these values in accordance with operation manuals of connected equipment As a rule household appliances can operate safely at 10 supply voltage deviation i e in the range...

Page 7: ...ameters will be saved in the voltage relay nonvolatile memory in 5 seconds after the last button press At that the SAVE inscription will be displayed for a short time the voltage relay enters the operation mode with new settings and the zero time reference will start to switch on the relay output When the protection actuation parameters of the voltage relay have been set connect protected equipmen...

Page 8: ... supply network will blink by turns on the display on operation of high voltage protection or the Lo symbol and voltage value in the power supply network on operation of low voltage protection The voltage relay will be in this mode as long as the voltage in the power supply network returns to the range of values from UL 5 V to UH 5 V The relay enters the turn on delay mode after its connection to ...

Page 9: ... to increase power supply voltage V delay time sec Dimensions mm Value 220 230 50 15 3 3 125 not more than 0 3 sec 100 300 150 210 1 V step 230 265 1 V step 5 999 1 sec step 53 116 80 Notes Technical specifications given in this table are supplemental informa tion and cannot give occasion to claims Technical specifications and package contents are subject to change without notice due to the improvem...

Page 10: ... Гарантийный срок 12 мес Срок службы 2 года Производитель СВЕН ПТЕ Лимитед 176 Джу Чиат Роуд 02 02 Сингапур 427447 Произведено под контролем Свен Скандинавия Лимитед 48310 Финляндия Котка Котолахдентие 15 Сделано в Китае Manufacturer SVEN PTE LTD 176 Joo Chiat Road 02 02 Singapore 427447 Produced under the control of Oy Sven Scandinavia Ltd 15 Kotolah dentie Kotka Finland 48310 Made in China Regis...