background image

 
 

  FCC Interference Statement

 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. 

 

These limits are designed to provide reasonable protection against harmful interference in a 

residential installation. 

 

This equipment generates, uses and can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful interference to radio 

communications. 

 

However, there is no guarantee that interference will not occur in a particular installation. 

 

If this equipment does cause harmful interference to radio or television reception, which

 

can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one of the following measures:

 

• Reorient or relocate the receiving antenna.

 

• Increase the separation between the equipment and receiver.

 

• Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected.

 

• Consult the dealer or an experienced radio/TV technician for help.

 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 

conditions:

 

(1) This device may not cause harmful interference, and

 

(2) This device must accept any interference received, including interference that may cause 

undesired operation.

 

FCC Caution: Any changes or modifications not expressly approved by the party responsible for 

compliance could void the user's authority to operate this equipment.

 

This transmitter must not be co-located or operating in conjunction with any other antenna or 

transmitter.

 

警語

警語

警語

警語

:

 

「取得審驗證明之低功率射頻器材

取得審驗證明之低功率射頻器材

取得審驗證明之低功率射頻器材

取得審驗證明之低功率射頻器材,

,非經核准

非經核准

非經核准

非經核准,

,公司

公司

公司

公司、

、商號或使用者均

商號或使用者均

商號或使用者均

商號或使用者均

不得擅自變更頻率

不得擅自變更頻率

不得擅自變更頻率

不得擅自變更頻率、

、加大功率或變更原設計之特性及功能

加大功率或變更原設計之特性及功能

加大功率或變更原設計之特性及功能

加大功率或變更原設計之特性及功能。

 

低功率射頻器材之使用不得影響

低功率射頻器材之使用不得影響

低功率射頻器材之使用不得影響

低功率射頻器材之使用不得影響飛航安全及干擾合法通信

飛航安全及干擾合法通信

飛航安全及干擾合法通信

飛航安全及干擾合法通信;

;經發現有干

經發現有干

經發現有干

經發現有干

擾現象時

擾現象時

擾現象時

擾現象時,

,應立即停用

應立即停用

應立即停用

應立即停用,

,並改善至無干擾時方得繼續使用

並改善至無干擾時方得繼續使用

並改善至無干擾時方得繼續使用

並改善至無干擾時方得繼續使用。

 

前述合法通信

前述合法通信

前述合法通信

前述合法通信,

,指依電信管理法規定作業之無線電通信

指依電信管理法規定作業之無線電通信

指依電信管理法規定作業之無線電通信

指依電信管理法規定作業之無線電通信。

。低功率射頻器

低功率射頻器

低功率射頻器

低功率射頻器

材須忍受合法通信或工業

材須忍受合法通信或工業

材須忍受合法通信或工業

材須忍受合法通信或工業、

、科學及醫療用電波輻射性電機設備之干擾

科學及醫療用電波輻射性電機設備之干擾

科學及醫療用電波輻射性電機設備之干擾

科學及醫療用電波輻射性電機設備之干擾。」

。」

。」

。」

 

 

 

Summary of Contents for PAD02

Page 1: ...eplace only with same type and rating of fuse 3 Do not connect any appliances other than luminary products 4 Do not connect any appliances to this remote controlled lampholder which are radiating heat and may cause ignition or burning of surrounding materials for example radiation heaters portable heaters portable floodlights desk lamps etc 5 Take into consideration that connected appliances might...

Page 2: ...h Set the ON OFF switch of the attached load to ON The dimmer LED illuminating but the detector cannot control the dimmer 1 Not carry out association 2 Same frequency interference 1 Carry out association 2 Wait for a while to re try Screw lampholder Type Since the socket type for each country in Europe varies refer to the outline for each socket suited for each country as follows EU TYPE PAD02 1 U...

Page 3: ...econds Unlike inclusion function as shown in the table below the execution of auto inclusion is free from pressing the On Off button on the dimmer The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z WaveTM certificated primary controller to access the setup function and to Add Remove Associate devices Function Description Annotation No n...

Page 4: ...ode ID the LED flashes on and off alternately at 2 second intervals By pressing On Off button it will stop flashing temporarily Learning When PAD02 is in learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Manual dim level control To manually switch on the light press and release the On Off button shortly when the light is off The light will dim from off to the ...

Page 5: ...hing to do is unplug PAD02 and reduce the load Then re plug PAD02 and it will work again The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 2 1 2 Device reset locally notification When PAD02 is reset manually it will send a DEVICE_RESET_LOCALLY_ NOTIFICATION to the nodes of group 1 2 1 3 Multilevel switch report Whenever the level of ...

Page 6: ...MMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_MULTILEVEL_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ALARM COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_SCENE_ACTIVATION COMMAND_CLASS_SCENE_ACTUATOR_CONF Choosing a Suitable Location 1 Do not locate the dimmer facing direct sunlight humid or dusty place 2 The sui...

Page 7: ...help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s au...

Reviews: