Product Overview 

 

 

 

 

 

 

 
 
 
 
 
 
 

For Instruction to http:// 

www.philio-tech.com 

 

 

 

 

 

 

 

 

 

 

 

 

 

Adding to Z- Wave

TM

 Network

 

In the front casing, there is an on/off button with LED indicator below which is used to 

switch on and off, dim level, or carries out add, remove, reset or association.

 

When first power is applied, its LED flashes on and off alternately and repeatedly at 

0.5 second intervals. It implies that it has not been assigned a node ID and start auto 

inclusion.

 

Auto Inclusion

 

The function of auto inclusion will be executed as long as the dimmer does not

 

have Node ID and just connect the dimmer to main power.

 

Note: Auto inclusion timeout is 2 minute during which the node information of explorer 

frame will be emitted once every several seconds. Unlike “inclusion” function as 

shown in the table below, the execution of auto inclusion is free from pressing the 

On/Off button on the dimmer.

 

The table below lists an operation summary of basic Z-Wave functions. Please refer

 

to the instructions for your Z- Wave

TM

   

certificated primary controller to access the

 

setup function, and to Add/Remove/Associate devices

 

 

Function

 

Description

 

Annotation

 

No node ID

 

The Z-Wave Controller does not allocate 
a node ID to the Switch.

 

LED 2-second on, 2-second 
off

 

Add

 

(Inclusion)

 

1. 

Put your Z-Wave controller into

 

inclusion mode by following the

 

instructions provided by the

 

controller manufacturer.

 

 

2.    Pressing Include button of PAD02 

three times within 2 seconds will 
enter inclusion mode.

 

Remove

 

(Exclusion)

 

1.

 

Put your Z-Wave controller into

 

exclusion mode by following the

 

instructions provided by the

 

controller manufacturer.

 

 

On/off Button, Learn key and 

Dimmer key (dimmer on status)

 

Summary of Contents for PAD02

Page 1: ...eplace only with same type and rating of fuse 3 Do not connect any appliances other than luminary products 4 Do not connect any appliances to this remote controlled lampholder which are radiating heat and may cause ignition or burning of surrounding materials for example radiation heaters portable heaters portable floodlights desk lamps etc 5 Take into consideration that connected appliances might...

Page 2: ...h Set the ON OFF switch of the attached load to ON The dimmer LED illuminating but the detector cannot control the dimmer 1 Not carry out association 2 Same frequency interference 1 Carry out association 2 Wait for a while to re try Screw lampholder Type Since the socket type for each country in Europe varies refer to the outline for each socket suited for each country as follows EU TYPE PAD02 1 U...

Page 3: ...econds Unlike inclusion function as shown in the table below the execution of auto inclusion is free from pressing the On Off button on the dimmer The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z WaveTM certificated primary controller to access the setup function and to Add Remove Associate devices Function Description Annotation No n...

Page 4: ...ode ID the LED flashes on and off alternately at 2 second intervals By pressing On Off button it will stop flashing temporarily Learning When PAD02 is in learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Manual dim level control To manually switch on the light press and release the On Off button shortly when the light is off The light will dim from off to the ...

Page 5: ...hing to do is unplug PAD02 and reduce the load Then re plug PAD02 and it will work again The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 2 1 2 Device reset locally notification When PAD02 is reset manually it will send a DEVICE_RESET_LOCALLY_ NOTIFICATION to the nodes of group 1 2 1 3 Multilevel switch report Whenever the level of ...

Page 6: ...MMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_MULTILEVEL_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_ALARM COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 COMMAND_CLASS_SCENE_ACTIVATION COMMAND_CLASS_SCENE_ACTUATOR_CONF Choosing a Suitable Location 1 Do not locate the dimmer facing direct sunlight humid or dusty place 2 The sui...

Page 7: ...help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s au...

Reviews: