background image

Slim Multi-sensor PST07                          

The   multi   sensor   is   a   Z-WaveTM   enabled   device   which   is   fully
compatible   with   any   Z-WaveTM   enabled   network.   This   device   is   a
security enabled Z-Wave Plus product that is able to use encrypted Z-
Wave   Plus   messages   to   communicate   to   other   security   enabled   Z-
Wave   Plus   products.   Z-WaveTM   enabled   devices   displaying   the   Z-
WaveTM logo can also be used with it regardless of the manufacturer,
and ours can also be used in other manufacturer’s Z-WaveTM enabled
networks.
The   product   supports   Over   The   Air(OTA)   feature   for   the   products
firmware upgrade.

This product can be included and operated in any Z-Wave

TM

  network

with other Z-Wave

TM

 certified devices from other manufacturers and/or

other applications.   All non-battery operated nodes within the network
will act as repeaters regardless of vendor to increase reliability of the
network.

The device adopt the Z-Wave

TM

 500 series chip, when your Z-Wave

TM

network   system   is   all   made   by   Z-Wave

TM

  500   series   devices.   The

network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Add to/Remove from Z-Wave

TM

 Network

There   are   two   tamper   keys   in   the   device,   one   is   in   the   back   side,
another  is  in the front side. Both of them can add, remove, reset or
association from Z-Wave

TM

 network.

The table below lists an operation summary of basic Z-Wave functions. 
Please refer
to the instructions for your Z-WaveTM Certificated Primary Controller to 
access the
Setup function, and to Add/Remove/associate devices

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means “

Remove

” or “

Exclusion

”.

Function

Description

Add

1.

Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing tamper key three times within 2 seconds 

to enter the inclusion mode.

3.

After add successful, the device will wake to 
receive the setting command from Z-Wave

TM

 

Controller about 20 seconds.

Remove

1.

Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing tamper key three times within 2 seconds 

to enter the exclusion mode.
Node ID has been excluded.

1

Summary of Contents for PST07

Page 1: ...eTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association from Z WaveTM network The table below lists an operation summary of basic Z Wave fu...

Page 2: ...val minimum setting is 30 minutes and maximum setting is 120 hours And the interval step is 30 minutes If the user want to wake up the device immediately please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report When the PIR motion triggered the device will report the trigger event and also report the battery status temperature and illum...

Page 3: ...NO 14 Low battery report When the battery level is too low every 30 minutes will report once LightSensor level report Every 6 hours report once in default It could be changed by setting the configuration NO 15 Temperature report Every 6 hours report once in default It could be changed by setting the configuration NO 16 Notice The configuration NO 14 15 and 16 could be setting to zero to disable th...

Page 4: ...D will flash once But in the Test Mode the LED also will light ON one second When the event triggered the device will emit the signal to turn ON the lighting equipment those nodes are in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the configuration NO 13 The PIR motion re detected interval in the Test Mode fixed to 10 seconds In the Normal Mode it ...

Page 5: ...guration the data size is 1 The configuration mark with star means after the remove the setting still keep don t reset to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no effect 5 ...

Page 6: ...illumination detected function And never turn on the light 1 means darkest 100Lux 99 means brightest 100 means turn off illumination N O Name Def Valid Description detected function And always turn on the light Notice In none test mode only the value in 1 to 99 will enable the illumination detected function and update the illumination value 5 LightSensor Threshold line 2 2 1 100 0 means turn off i...

Page 7: ...ve 0 Bit4 Reserve 0 Bit5 Reserve 0 Bit6 Reserve 0 Bit7 Reserve 10 Mult Sensor Function Switch 0 All Multisensor function switch Using bit to control Caution The value is unsigned N O Name Def Valid Description byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bit1 Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2 1 Disable 0 Enable 0 Bit2 Reserve 0 Bit3 Re...

Page 8: ...figuration No 17 15 Auto Report LightSensor Time 12 0 127 The interval time for auto report the illumination 0 means turn off auto report N O Name Def Valid Description illumination The default value is 12 The tick time can setting by the configuration No 17 16 Auto Report Temperature Time 12 0 127 The interval time for auto report the temperature 0 means turn off auto report temperature The defau...

Page 9: ...C 24 Temperature Threshold line 5 40 20 50C Temperature difference return The default is 40 degrees C 25 PIR Trigger Mode 1 1 3 PIR Trigger Mode Mode1 Normal Mode2 DayTime N O Name Def Valid Description Mode3 AtNight 26 PIR NightLine 1 1 100 PIR night line Lux conditions LightSensor determines whether the level is night Unit 100Lux Z Wave Supported Command Class Command Class Version Required Secu...

Page 10: ... recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C www philio tech com FCC int...

Page 11: ...hanges or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for info...