Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can
adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128
… 255 the value sent in the application shall be the desired value minus 256. For example: to set a
parameter to 200? it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value
the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Basic Set Level (Parameter Number 2, Parameter Size 1) Setting the BASIC command value to turn on the
light
Value
Description
255
0xFF(-1) turns on the light. (Default)
1 — 100 For dimmers 1 to 100 means the light strength
Light Threshold (Parameter Number 4, Parameter Size 1) Setting the illumination threshold to turn on the
light. When the event triggered and the environment illumination lower then the threshold, the device will
turn on the light
Value
Description
0
0 means turn off illumination detected function And never turn on the light.
1 — 100
1 means darkest. 99 means brightest. 100 means turn off illumination detected function.
And always turn on the light (Default 99)
Operation Mode (Parameter Number 5, Parameter Size 1) parameter to set the Operation Mode
Value
Description
0 — 127
Bit 0: Reversed. Bit 1: Reversed. Bit 2: Disable the door/window function. Bit 3: Setting the
temperature scale. 0: Fahrenheit, 1:Celsius Bit 4: Disable illumination report after event
triggered. Bit 5: Disable temperature report after event triggered. (Default 0)