Multi-Sensor Function Switch (Parameter Number 6, Parameter Size 1) parameter to set the sensor
functions
Value
Description
0 —
127
Bit 0: Disable magnetic integrate illumination. Bit 1: Reserved, always 1. Bit 2: Reserved, always
1. Bit 3: Reserved. Bit 4: Disable delay 5 seconds to turn off the light, when door/window closed.
Bit 5: Disable auto turn off the light, after door/window opened to turn on the light. Bit 6:Enable
temperature monitoring. When this bit enable, the temperature changed 3 degree Fahrenheit, it
will report. And also the temperature over 140 degree Fahrenheit, it will report every 64 seconds.
(Default 4)
Turn Off Light Time (Parameter Number 9, Parameter Size 1) After turn on the light, setting the delay time to
turn off the light when the PIR motion is not detected
Value
Description
4 — 127 8 seconds per tick, and minimum time is 32 seconds, default tick is 4 (32 seconds) (Default 4)
Auto Report Battery Time (Parameter Number 10, Parameter Size 1) interval time for auto report the battery
level
Value
Description
1 — 127 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) (Default 12)
Auto Report Door/Window State Time (Parameter Number 11, Parameter Size 1) interval time for auto
report the door/window state
Value
Description
1 — 127 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) (Default 12)
Auto Report Temperature Time (Parameter Number 12, Parameter Size 1) interval time for auto report the
temperature
Value
Description
1 — 127 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) (Default 12)
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 6