background image

Firmware Update Meta Data

4

Highest granted Security Class

Supervision

1

None

Transport Service

2

None

Overview

Specifications

Operating Voltage

DC5V (USB Type A)

Operating Temperature

-10°C ~ 55°C (85% humidity)

Storage Temperature

-20 C ~ 60°C

RF Range (distance)

Minimum 40M in door and 100M in outdoor, line
of sight

Frequency Range

868.40MHz; 869.85MHz (EU)

908.40MHz; 916.00MHz (US)

916.00 MHz (IL), (Israel), (

PAU05

-IL)

922~927MHz (Japan)

920~924MHz (Taiwan; Korea)

865.20 MHz (IN),

869.00 MHz (RU),

921.40 MHz, 919.80 MHz (ANZ),

RF Maximum Power (peak)

+5dBm (peak)

RF Maximum Power 

-10dBm (Average)

(Average)

RF Modulation Type

FSK (Frequency-Shift Keying)

** Specifications are subject to change and improvement without notice.

     

   

      

FCC ID: RHHPAU05     

                                    

FCC Interference Statement

This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide   reasonable   protection   against   harmful   interference   in   a   residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference   to   radio   communications.   However,     there   is   no   guarantee   that
interference will not occur in a particular installation.   If this equipment does cause
harmful interference  to radio or television  reception, which  can  be determined by
turning   the   equipment   off   and   on,     the   user   is   encouraged   to   try   to   correct   the
interference by one of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.

3

Summary of Contents for PAU05

Page 1: ...oller does not allocate a node ID to the Switch LED 2 second on 2 second off Blue LED Add Inclusion 1 Put your Z Wave controller into inclusion mode by following the instructions provided by the controller manufacturer 2 Pressing Include button of PAU05 three times within 2 seconds will enter inclusion mode Remove Exclusion 1 Put your Z Wave controller into exclusion mode by following the instruct...

Page 2: ...health Press the button once to enter the network health test According to the test results the LED light will flash three times LED color meaning is as follows LED color Description Green Network health is good Yellow Network health is acceptable but latency can be observed occasionally Red Network health is insufficient because frames are dropped 2 Z Wave s Configuration Configuration Parameter ...

Page 3: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio ...

Page 4: ...he return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling www philio tech com Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local g...

Reviews: