background image

 
 

 

PAN16

 

Smart energy plug in switch

 

P     

         

       
 
                                                                                           
 
 
 
 

 

This plug-in ON/OFF switch PAN16 is a security enabled  wireless switch, based on 
Z-Wave  Plus  technology.  Z-Wave  Plus

TM

  enabled  devices  displaying  the  Z-Wave 

Plus

TM

 logo can also be used with it regardless of the manufacturer, and can also be 

used in other manufacturer’s Z-Wave

TM

 enabled networks. Remote On/Off control of 

the  connected  load  is  possible  with  other  manufacturer’s  wireless  Controller.  Each 
switch  is  designed  to  act  as  a  repeater.  Repeaters  will  re-transmit  the  RF  signal  to 
ensure  that  the  signal  is  received  by  its  intended  destination  by  routing  the  signal 
around obstacles and radio dead spots. Because PAN16 supports Security Command 
Class, it can learn with Secured controller. Its functionality and supported command 
classes is identical when included as a secure and non-secure device.

 

 
This  plug-in  ON/OFF  switch  is  able  to  detect  instance  wattage  (3000W/230Vac) 
(13Ampere)  and  overload  current  (14.5A  with  resistive  load)  of  connected  lights  or 
appliances. When detecting overload state, the Switch will be disabled and its On/Off 
button  will  be  lockout  of  which  LED  will  flash  quickly.    However,  unplug  and 
re-connect the switch will reset its overload condition to normal status.

 

 

Adding to Z-Wave

TM

 Network

 

 
In the front casing, there is an On/Off button with LED indicator which is used to toggle 
switch  on  and  off  or  carry  out  inclusion,  exclusion,  reset  or  association.  When  first 
power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second 
intervals. It implies that it has not been assigned a node ID and start auto inclusion. 

 

 

Auto Inclusion

 

 
The function of auto inclusion will be executed as long as the switch does not have

 

Node ID and just plug the switch into a wall outlet.

 

 
Note:

 Auto inclusion timeout is 2 minute during which the node information of explorer 

frame will be emitted once several seconds. Unlike “inclusion” function as shown in 
the table below, the execution of auto inclusion is free from pressing the On/Off button 
on the Switch.

 

 
The table below lists an operation summary of basic Z-Wave functions. Please refer to 
the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the Setup 

function, and to Add/Remove/Associate devices

 

 

Function

 

Description

 

Annotation

 

No node ID

 

The Z-Wave Controller does not allocate 
a node ID to the Switch.

 

LED 2-second on, 2-second 
off

 

Add

 

1.

 

Put your Z-Wave controller into 
inclusion mode by following the 
instructions provided by the 
controller manufacturer.

 

 

2.    Pressing On/Off button three times 

within 2 seconds will enter inclusion 
mode.

 

Remove

 

1.

 

Put your Z-Wave controller into 
exclusion mode by following the 
instructions provided by the 
controller manufacturer.

 

 

2.

 

Pressing On/Off button three times 
within 2 seconds will enter exclusion 
mode.

 

Summary of Contents for PAN16

Page 1: ...Off button with LED indicator which is used to toggle switch on and off or carry out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 0 5 second intervals It implies that it has not been assigned a node ID and start auto inclusion Auto Inclusion The function of auto inclusion will be executed as long as the switch does no...

Page 2: ...ternately at 2 second intervals By pressing On Off button it will stop flashing temporarily Learning When PAN16 is in learning mode LED flashes on and off alternately and repeatedly at 0 5 second intervals Overload When overload state occurs the Switch is disabled of which LED flashes on and off alternately at 0 2 second intervals Overload state can be cleared by unplugging and reconnecting the Sw...

Page 3: ...e Switch will report its latest status to Z Wave Controller Grouping 1 includes SWITCH_BINARY_REPORT METER_REPORT ALARM_REPORT 2 1 Auto report to Grouping 1 Maximum Node 1 2 1 1 On Off Event Report When on or off state has been changed it will send Binary Switch Report to the node of Grouping 1 Binary Switch Report ON Command Class Switch Binary Switch Binary Report Value 255 0xFF OFF Command Clas...

Page 4: ...learing accumulated power consumption Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC load Voltage V When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command ...

Page 5: ... 0 01A 14 5A 3 1 Watt Meter Report Period If the setting is configured for 1hour set value 720 PAN16 will report its instant power consumption to Group1 node every 1 hour The maximum interval to report its instant power consumption is 45 hours 5s 32767 3600 45hr When the setting is 0 PAN16 will disable Watt auto report function The default value is 720 3 2 KWH Meter Report Period If the setting is...

Page 6: ...enever PAN16 is repowered it will check this parameter for if sending a BINARY_SWITCH_ REPORT to the node of group1 or not The default setting is Disable the function 3 12 Adjustable Overload The overload current can be adjustable from 4 5A to 14 5A The default value is 1450 for 14 5A 1450 0 01A 14 5A 4 Protection Command Classes PAN16 supports Protection Command Class version 2 it can protect the...

Page 7: ...1 France type PAN16 2 UK type PAN16 3 Switzerland type PAN16 4 Note Please make sure that the intensity of the plug of the electrical device must be 16A and have same head as the enclosed plug before inserting to the socket ...

Page 8: ...oad occurs Remove the load attached or check max load cannot exceed 13A Resistive load Specification Operating Voltage 220V 240V 50Hz for EU Type Operating Voltage 100V 120V 50Hz 60Hz for US Type Maximum Load Ampere 13A Resistive load PAN16 1 PAN16 2 PAN16 3 Maximum Load Ampere 10A Resistive load PAN16 4 Switzerland Socket Type Germany type PAN16 1 France type PAN16 2 UK type PAN16 3 Switzerland t...

Page 9: ...ccordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the follow...