EN
21
EN
Option A
Option B
fig. 4
Under any circumstances, make sure the Induction cooker hob is well ventilated and the air
inlet and outlet are not blocked. Ensure the induction cooker hob is in good work state. As
shown below
Note: The safety distance between the hot plate and the cupboard above the
hot plate should be at least 650mm.
A(mm) B(mm) C(mm) D
E
650
35 mini 20 mini Air intake Air exit 5mm
Before you install the hob, make sure that
1. The work surface is square and level, and no structural members interfere with space
requirements.
2. The work surface is made of a heat-resistant material.
3. If the hob is installed above an oven, the oven has a built-in cooling fan.
4. The installation will comply with all clearance requirements and applicable standards
and regulations.
5. A suitable isolating switch providing full disconnection from the mains power supply is
incorporated in the permanent wiring, mounted and positioned to comply with the
local wiring rules and regulations.
6. The isolating switch must be of an approved type and provide a 3 mm air gap contact
separation in all poles (or in all active [phase] conductors if the local wiring rules
allow for this variation of the requirements) the isolating switch will be easily
accessible to the customer with the hob installed.