background image

 

 
 

Safety Procedures – General Precautions 

WWW.PHIHONG.COM 

General

  -  Please  read  the  following  precautions  carefully  before  installing  and  connecting  the 

system to a power source.   

Note

 – Only qualified and trained service personnel (in accordance with IEC 60950 and AS/NZS 

3260)  should  install,  replace,  or  service  the  equipment.    Install  the  system  in  accordance  with 
Country, National or to the U.S. National Electric Code if you are in the United States. 

 Precautions:

 

1.

 

The building facilities in which the product will be used must provide Isolation to the main 
AC Input connector. This connection requires a fuse or circuit breaker no larger than 20A for 
120 VAC (U.S.A.) or 16A, 230 VAC (international).  The building facilities must protect the 
POE62U Power injector from over current or short-circuits. 

2.

 

The  POE62U  power  injector  enclosure  is  IP67  tested  which  provides  degrees  of  protection 
against  access  to  hazardous  parts,  dust  and  against  ingress  of  water.  To  ensure  protection 
against  ingress  of  water,  torque  captive  screws  (4  places)  in  an  “X”  pattern  to  >  27  inch 
pound.    –Only  qualified  service  personal  should  install,  replace  or  service  this  equipment. 
Before  connecting,  visit  “www.phihong.com”  for  the  latest  up  to  date  specification  and 
contact information.  

3. 

The  POE62U  power  injector  enclosure  must  be  mounted  vertically  but  not  orientation 
limited.  The  enclosure  is  provided  with  a  steel  2mm  thick  zinc  plated  mounting  bracket. 
When mounting utilize the holes in the mounting bracket plate (10mm holes) 8 places. The 
preferred  method  of  mounting  is  to  a  vertical  4  inch  or  6  inch  pole  using  2”3/8  x  16”  U-
bolts. If mounting on a flat surface, to  sheetrock  or wood  and or others  material,  use 4 M6 
fasteners. Other fasteners may be used, but hardware must be sized to support 4-5 times the 
weight of the unit.

  

4. 

The  POE62U  power  injector  enclosure  has  3  threaded  (¾  NPT)  openings  to  accommodate 
waterproof  /  water  tight  conduit  and  or  cable  glands.    WARNING:  To  ensure  protection 
against  ingress  of  water,  the  connection(s)  of  the  conduit  and  or  cable  glands  are  threaded 
with Teflon tape all the way through the holes in an enclosure wall. 

 

5. 

 The POE62U power injector AC input connector (located inside enclosure) is a 3 pin terminal 
block  9.5mm,  rated  20  A,  250  V,  with  M3.5  Nickel  Plated  steel  screws.  The  incoming  3 
wire/cable  must  be  minimum  14AWG  and  or  in  accordance  with  Country,  National  Electric 
Code. 

 

6.

 

The  POE62U  Power  injector  consists  of  “Data  &  Power”  ports.  The  ports  are  providing 
TNV-1  outputs.    The  ports  use  RJ-45  data  sockets.    Do  not  connect  telephone  cables  into 
these  ports.    Only  RJ-45  data  cables  with  waterproof  /  water  tight  connections  may  be 
connected to these sockets. 

7.

 

To prevent  the POE62U Power injector from overheating, do not  operate the product  in  an 
area that exceeds the maximum recommended ambient temperature of -40 ºC to +60 ºC.   

Summary of Contents for POE62U-560G

Page 1: ...ccess Points Safety Approvals cUL UL CE Mechanical Characteristics without Mounting Bracket Length 252 1mm 9 93in Height 78mm 3 07in Width 176mm 6 93in Weight 1 7Kg 3 75lb Mechanical Characteristics with Mounting Bracket Length 300mm 11 81in Height 82mm 3 23 Width 184mm 7 24in Weight 2 83kg 6 24lb Output Specifications Notes 1 Consult factory for availability Phihong is not responsible for any err...

Page 2: ... 5 to 90 EMI FCC Part 15 Class B EN55022 Class B Isolation Test Primary to Secondary 4242 VDC for 1 minute 10mA Primary to Field Ground 2121VDC for 1 minute 10mA Output to Field Ground 2121VDC for 1 minute 10mA Immunity ESD IEC61000 4 2 Level 3 RS IEC61000 4 3 Level 3 EFT IEC61000 4 4 Level 2 Surge IEC61000 4 5 Level 3 CS IEC61000 4 6 Level 3 Voltage Dips IEC61000 4 11 Harmonic EN61000 3 2 Class A...

Page 3: ...GLAND750 with fully waterproof AC and RJ45 cables Network Switch Network Switch must be Environment Rated B as per paragraph 33 4 1 1 of the IEEE802 3at standard POE62U Dimension Diagram unit mm Single Cable Gland PGLAND750 Dimension Diagram unit mm Double Cable Gland PGLAND750 2 Dimension Diagram unit mm Note Cable Glands are sold separately ...

Page 4: ...but not orientation limited The enclosure is provided with a steel 2mm thick zinc plated mounting bracket When mounting utilize the holes in the mounting bracket plate 10mm holes 8 places The preferred method of mounting is to a vertical 4 inch or 6 inch pole using 2 3 8 x 16 U bolts If mounting on a flat surface to sheetrock or wood and or others material use 4 M6 fasteners Other fasteners may be...

Page 5: ...by all appropriate National laws and regulations Installation Instructions 1 The unit is packaged fully closed with the mounting bracket pre installed remove from packaging and loosen the four captive screws located at the top of the midspan so that the lid can be lifted easily 2 Using a Philips screwdriver remove the four screws holding the protective covering for the PC Board and the two screws ...

Page 6: ... spade lugs Pair and secure ground line and neutral to the appropriate positions on the three pin terminal block and reattach the protective covering Note if using the cable gland PGLAND750 the outer seal nut needs to be fully tightened to close rubber seal to protect against ingress of water 6 Using waterproof outdoor rated Cat5e Ethernet cable thread through cable glands or conduit piping to the...