POE62U Characteristics 

WWW.PHIHONG.COM 

INPUT: 
AC Input Voltage Range 

90 to 264VAC 
 

AC Input Voltage Rating 

100 to 240VAC 
 

AC Input Current 

2.5A (RMS) and 90VAC at maximum load 
1.2A (RMS) and 240VAC at maximum load 
 

AC Input Frequency 

47 to 63Hz 
 

Leakage Current 

3.5mA for 254VAC, 50Hz 

 
Max Inrush Current 

50A for 115VAC at maximum load 
75A for 230VAC at maximum load 

 
OUTPUT: 
Total Output Power 

60W over 4 pairs at 60C 
75W over 4 pairs at 50C 
90W over 4 pairs at 40C 
 

Ripple and Regulation 

300mV maximum  
 

Efficiency 

70% (typical) at maximum load, and 
120VAC 60Hz 

 
ENVIRONMENTAL: 
Temperature 

Operation 

 

-40 to +60°C 

Non-operation  

-40 to +85°C

 

 
Humidity 

Operation 

 

5 to 90% 

 
 

EMI 

FCC Part 15 Class B 
EN55022 Class B  
 

Isolation Test 

Primary to Secondary: 4242 VDC for 1 
minute, 10mA  
Primary to Field Ground: 2121VDC for 1 
minute, 10mA 

Output to Field Ground: 2121VDC for 1 

minute, 10mA 
 

Immunity  

ESD: 

IEC61000-4-2  Level 3 

RS: 

IEC61000-4-3  Level 3 

EFT: 

IEC61000-4-4  Level 2 

Surge: 

IEC61000-4-5  Level 3 

CS: 

IEC61000-4-6  Level 3 

Voltage Dips  IEC61000-4-11 
Harmonic:  EN61000-3-2  Class A 

 
Insulation Resistance 

Primary to Secondary: >10M OHM 
500VDC 
Primary to Field Ground: >10M OHM 
500VDC 

 
FEATURES: 
Over Voltage/Current, Short Circuit 
Protection 

The output can be shorted permanently 
without damage 
 

Indicators 

LED 1: DC Good 
 

Input Connector 

3 pin terminal block with M3.5 screw 
terminal; for appropriate connection use 
minimum 14AWG wire and M3.5 spade lug  
 

Output PoE Connector 

RJ45 

 
Output PoE Connection 

+pins 3, 6, 4, 5 / -pins 1, 2, 7, 8 

 

Summary of Contents for POE62U-560G

Page 1: ...ccess Points Safety Approvals cUL UL CE Mechanical Characteristics without Mounting Bracket Length 252 1mm 9 93in Height 78mm 3 07in Width 176mm 6 93in Weight 1 7Kg 3 75lb Mechanical Characteristics with Mounting Bracket Length 300mm 11 81in Height 82mm 3 23 Width 184mm 7 24in Weight 2 83kg 6 24lb Output Specifications Notes 1 Consult factory for availability Phihong is not responsible for any err...

Page 2: ... 5 to 90 EMI FCC Part 15 Class B EN55022 Class B Isolation Test Primary to Secondary 4242 VDC for 1 minute 10mA Primary to Field Ground 2121VDC for 1 minute 10mA Output to Field Ground 2121VDC for 1 minute 10mA Immunity ESD IEC61000 4 2 Level 3 RS IEC61000 4 3 Level 3 EFT IEC61000 4 4 Level 2 Surge IEC61000 4 5 Level 3 CS IEC61000 4 6 Level 3 Voltage Dips IEC61000 4 11 Harmonic EN61000 3 2 Class A...

Page 3: ...GLAND750 with fully waterproof AC and RJ45 cables Network Switch Network Switch must be Environment Rated B as per paragraph 33 4 1 1 of the IEEE802 3at standard POE62U Dimension Diagram unit mm Single Cable Gland PGLAND750 Dimension Diagram unit mm Double Cable Gland PGLAND750 2 Dimension Diagram unit mm Note Cable Glands are sold separately ...

Page 4: ...but not orientation limited The enclosure is provided with a steel 2mm thick zinc plated mounting bracket When mounting utilize the holes in the mounting bracket plate 10mm holes 8 places The preferred method of mounting is to a vertical 4 inch or 6 inch pole using 2 3 8 x 16 U bolts If mounting on a flat surface to sheetrock or wood and or others material use 4 M6 fasteners Other fasteners may be...

Page 5: ...by all appropriate National laws and regulations Installation Instructions 1 The unit is packaged fully closed with the mounting bracket pre installed remove from packaging and loosen the four captive screws located at the top of the midspan so that the lid can be lifted easily 2 Using a Philips screwdriver remove the four screws holding the protective covering for the PC Board and the two screws ...

Page 6: ... spade lugs Pair and secure ground line and neutral to the appropriate positions on the three pin terminal block and reattach the protective covering Note if using the cable gland PGLAND750 the outer seal nut needs to be fully tightened to close rubber seal to protect against ingress of water 6 Using waterproof outdoor rated Cat5e Ethernet cable thread through cable glands or conduit piping to the...

Reviews: