OPENING TIMES – LOW ENERGY POWER OPEN DOOR
0º
0º (closed) to 60º BACKCHECK position
Minimum opening time
to 80º or Backcheck,
whichever occurs first,
is 3 to 5.5 seconds
depending on weight
and width of door
(refer to TABLE
I
)
90º
60º
5.5
5.0
4.5
4.5
4.0
48 (1219)
4.5
4.5
4.0
4.0
3.5
42 (1067)
4.0
4.0
3.5
3.5
3.0
36 (914)
3.5
3.0
3.0
3.0
3.0
30 (762)
200 (90.7)
175 (79.4)
150 (68.0)
125 (56.7)
100 (45.4)
TABLE
I
“W” Door Weight in Pounds (kg)
“D” Door Leaf Width -
Inches (mm)